Monte Carlo simulation of TrueBeam flattening‐filter‐free beams using Varian phase‐space files: comparison with experimental data

MF Belosi, M Rodriguez, A Fogliata, L Cozzi… - Medical …, 2014 - Wiley Online Library
Purpose: Phase‐space files for Monte Carlo simulation of the Varian TrueBeam beams have
been made available by Varian. The aim of this study is to evaluate the accuracy of the …

Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode

Z Feng, H Yue, Y Zhang, H Wu, J Cheng, X Su - Radiation Oncology, 2016 - Springer
Abstract Purpose Through the Monte Carlo (MC) simulation of 6 and 10 MV flattening-filter-
free (FFF) beams from Varian TrueBeam accelerator, this study aims to find the best incident …

Comparison between the TRS-398 code of practice and the TG-51 dosimetry protocol for flattening filter free beams

JE Lye, DJ Butler, CP Oliver, A Alves… - Physics in Medicine …, 2016 - iopscience.iop.org
Dosimetry protocols for external beam radiotherapy currently in use, such as the IAEA TRS-
398 and AAPM TG-51, were written for conventional linear accelerators. In these …

Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters

W Cho, KN Kielar, E Mok, L Xing, JH Park… - Medical …, 2011 - Wiley Online Library
Purpose: With the introduction of flattening filter free (FFF) linear accelerators to radiation
oncology, new analytical source models for a FFF beam applicable to current treatment …

Monte Carlo comparison of superficial dose between flattening filter free and flattened beams

K Javedan, V Feygelman, RR Zhang, EG Moros… - Physica medica, 2014 - Elsevier
This study investigates the superficial dose from FFF beams in comparison with the
conventional flattened ones using a Monte Carlo (MC) method. Published phase-space files …

Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac

J Cashmore, S Golubev, JL Dumont, M Sikora… - Medical …, 2012 - Wiley Online Library
Purpose: A linac delivering intensity‐modulated radiotherapy (IMRT) can benefit from a
flattening filter free (FFF) design which offers higher dose rates and reduced accelerator …

Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR

T Teke, C Duzenli, A Bergman, F Viel, P Atwal… - Medical …, 2015 - Wiley Online Library
Purpose: To establish the clinical acceptability of universal Monte Carlo phase–space data
for the 10XFFF (flattening filter free) photon beam on the Varian TrueBeam Linac, including …

Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm

J Hrbacek, S Lang, S Klöck - International Journal of Radiation Oncology …, 2011 - Elsevier
PURPOSE: To investigate dosimetric characteristics of a new linear accelerator designed to
deliver flattened, as well as flattening filter-free (FFF), beams. To evaluate the accuracy of …

Monte Carlo study of in‐field and out‐of‐field dose distributions from a linear accelerator operating with and without a flattening‐filter

SS Almberg, J Frengen, T Lindmo - Medical physics, 2012 - Wiley Online Library
Purpose: To compare dosimetric characteristics of 6 MV photon fields originating from a
linear accelerator operating with (FF) and without (FFF) a flattening‐filter. The main objective …

A geometrical model for the Monte Carlo simulation of the TrueBeam linac

M Rodriguez, J Sempau, A Fogliata… - Physics in Medicine …, 2015 - iopscience.iop.org
Monte Carlo simulation of linear accelerators (linacs) depends on the accurate geometrical
description of the linac head. The geometry of the Varian TrueBeam linac is not available to …