Combined automatic implantable cardioverter-defibrillator and pacemaker systems: implantation techniques and follow-up

AE Epstein, GN Kay, VJ Plumb, RB Shepard… - Journal of the American …, 1989 - Elsevier
The automatic implantable cardioverter-defibrillator (AICD) effectively prevents death due to
ventricular tachycardia or ventricular fibrillation. Some patients who need an AICD also …

Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators

H Calkins, J Brinker, EP Veltri, T Guarnieri… - Journal of the American …, 1990 - Elsevier
Concomitant use of a pacemaker and an automatic implantable cardioverter-defibrillator
(AICD) is common. Seventeen percent of patients receiving an AICD at The Johns Hopkins …

The use and interaction of permanent pacemakers and the automatic implantable cardioverter defibrillator

AI Cohen, MH Wish, RD Fletcher… - Pacing and Clinical …, 1988 - Wiley Online Library
The adverse interactions of permanent pacemakers and automatic implantable cardioverter
defibrillators (AICD) were studied in nine patients in whom both devices were implanted …

Automatic implantable cardioverter defibrillator/permanent pacemaker interaction: Loss of pacemaker capture following AICD discharge

M Slepian, JH Levine, L Watkins Jr… - Pacing and Clinical …, 1987 - Wiley Online Library
A 78‐year‐old man treated with amiodaronce for recurrent ventricular tachycardia, had
soquential placement of a bipolar VVI pacemaker and an automatic implantable cardioverter …

The Implantable Automatic Cardioverter-Defibrillator

H Klein, J Tröster, HJ Trappe, I Becht, F Siclari - Herz, 1990 - europepmc.org
In addition to medical treatment for ventricular tachyarrhythmias which has not proven to be
sufficient, nonmedical modes of treatment are available such as electrophysiologically …

Automatic implantable cardioverter defibrillator: Current status

AS Manolis, H Rastegar, NAM Estes - JAMA, 1989 - jamanetwork.com
The automatic implantable cardioverter defibrillator was conceived by Mirowski as an
implantable device for detection and termination of ventricular fibrillation. Since the initial …

Implanted automatic defibrillators: effects of drugs and pacemakers

I Singer, T Guarnieri… - Pacing and Clinical …, 1988 - Wiley Online Library
The automatic implantable cardioverter defibrillator is an effective device for prevention of
sudden ive device for prevention of sudden cardiac death. Patients who require the …

Permanent Pacing via Implantable Defibrillators.

SL Pinski, RG Trohman - Pacing & Clinical …, 2000 - search.ebscohost.com
Discusses the possibility of permanent cardiac pacing via implantable cardioverter-
defibrillators (ICD). Need for antibradycardia pacing in ICD recipients; Limitations of ICDs as …

Developments for future implantable cardioverters and defibrillators.

S Saksena, BD Lindsay… - Pacing & Clinical …, 1987 - search.ebscohost.com
Examines available information and identifies developments that would be relevant to the
next generation of implantable antitachycardia devices. Mechanisms underlying …

Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation

SG Kim, S Furman, LE Waspe, R Brodman… - The American journal of …, 1986 - Elsevier
The automatic implantable cardioverter-defibrillator (AICD®) 1–5 has been implanted in
over 500 patients with life-threatening ventricular arrhythmias. For detection of ventricular …