Effects of resterilization on mechanical properties of polypropylene meshes

K Serbetci, H Kulacoglu, AO Devay, N Hasirci - The American journal of …, 2007 - Elsevier
BACKGROUND: The re-use of sterile packaged polypropylene meshes in hernia surgery is
not recommended by the manufacturers. However, especially in developing and …

Effects of reactive oxygen species on the physical properties of polypropylene surgical mesh at various concentrations: a model for inflammatory reaction as a cause …

J Kurtz, B Rael, J Lerma, C Wright, T Khraishi… - Surgical …, 2016 - Springer
Background Oxidative degradation by reactive oxygen species (ROS) from inflammation
initiates cross-linking, depolymerization, and formation of a quasi-crystalline quality in …

Differences in polypropylene shrinkage depending on mesh position in an experimental study

MÁ García-Ureña, VV Ruiz, AD Godoy… - The American journal of …, 2007 - Elsevier
BACKGROUND: Polypropylene (PP) mesh is one of the most frequent materials used in
hernia repair. We have experimentally evaluated the shrinkage of PP mesh depending on …

Characterization of the structure and properties of authentic and counterfeit polypropylene surgical meshes

MK McDermott, IS Isayeva, TM Thomas, AS Lee… - Hernia, 2006 - Springer
A counterfeit version of the Ethicon Prolene polypropylene mesh was distributed to hospitals
and clinics and unintentionally implanted into patients undergoing tension-free hernia …

Searching for the best polypropylene mesh to be used in bowel contamination

A Díaz-Godoy, MA García-Ureña, J López-Monclús… - Hernia, 2011 - Springer
Purpose There is still some concern about the use of polypropylene in case of infection or
contamination. The biocompatibility of the recently introduced light-weight polypropylene …

In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) …

H Scheidbach, C Tamme, A Tannapfel… - Surgical Endoscopy and …, 2004 - Springer
Background: Polypropylene (PP) meshes are currently being used in millions of operations
for hernial repair. We tested several recently modified PP meshes to evaluate them in terms …

Analyzing material changes consistent with degradation of explanted polymeric hernia mesh related to clinical characteristics

X Lu, M Harman, B Todd Heniford, V Augenstein… - Surgical …, 2022 - Springer
Background Proposed mechanisms that potentially contribute to polypropylene mesh
degradation after in vivo exposure include oxidizing species and mechanical strains …

Characterization of heavyweight and lightweight polypropylene prosthetic mesh explants from a single patient

CR Costello, SL Bachman, SA Grant… - Surgical …, 2007 - journals.sagepub.com
Although polypropylene has been used as a hernia repair material for nearly 50 years, very
little science has been applied to studying the body's effect on this material. It is possible that …

Prevention of adhesions to polypropylene mesh in a rabbit model

RC Dinsmore, WC Calton Jr - The American Surgeon, 1999 - journals.sagepub.com
The purpose of this study was to develop a quantitative model for evaluating adhesion
formation and to determine whether Seprafilm (HAL-F) bioresorbable membrane (Genzyme …

Materials characterization of explanted polypropylene hernia mesh: patient factor correlation

SE Smith, MJ Cozad, DA Grant… - Journal of …, 2016 - journals.sagepub.com
This study quantitatively assessed polypropylene (PP) hernia mesh degradation and its
correlation with patient factors including body mass index, tobacco use, and diabetes status …