[HTML][HTML] Enhanced sensitivity and selectivity of an electrochemical sensor for real-time propofol monitoring in anesthesia

Y Gao, Y Guo, P He, Z Liu, Y Chen - Alexandria Engineering Journal, 2024 - Elsevier
In this study, an electrochemical sensor for the real-time monitoring of propofol (PPF) in
anesthesia was developed using molecularly imprinted polymers and reduced graphene …

Raspberry-Pi based system for propofol monitoring

F Stradolini, A Tuoheti, T Kilic, D Demarchi, S Carrara - Integration, 2018 - Elsevier
Induction of anesthesia with propofol is a largely adopted technique in hospital
environments. The correct dosage of this compound is essential to avoid under-or over …

Cytochrome P450 2B6 amperometric biosensor for continuous monitoring of propofol

DC Ferrier, J Kiely, R Luxton - IEEE Sensors Journal, 2021 - ieeexplore.ieee.org
Despite the growing evidence of improved patient outcomes and of a substantially reduced
environmental impact of propofol-based total intravenous anesthesia when compared to …

Toward feedback-controlled anesthesia: voltammetric measurement of propofol (2, 6-diisopropylphenol) in serum-like electrolyte solutions

F Kivlehan, F Garay, J Guo, E Chaum… - Analytical …, 2012 - ACS Publications
Propofol is a widely used, potent intravenous anesthetic for ambulatory anesthesia and long-
term sedation. The target steady state concentration of propofol in blood is 0.25–10 μg/mL (1 …

Propofol detection and quantification in human blood: the promise of feedback controlled, closed-loop anesthesia

F Kivlehan, E Chaum, E Lindner - Analyst, 2015 - pubs.rsc.org
The performance of a membrane-coated voltammetric sensor for propofol (2, 6-
diisopropylphenol) has been characterized in long term monitoring experiments using an …

Development of MIP sensor for monitoring propofol in clinical procedures

K Karim, L Giannoudi, E Piletska… - Journal of the …, 2015 - Taylor & Francis
Propofol is a widely used intravenous anaesthetic which requires close patient monitoring
that involves blood extraction methods. Polymers with high affinity for propofol were …

Electrochemical quantification of 2, 6-diisopropylphenol (propofol)

J Langmaier, F Garay, F Kivlehan, E Chaum… - Analytica chimica …, 2011 - Elsevier
2, 6-Diisopropylphenol (propofol) is a potent anesthetic drug with fast onset of the anesthetic
effect and short recovery time for the patients. Outside of the United States, propofol is widely …

Enhancing the sensitivity and selectivity of salbutamol detection using reduced graphene oxide combined with molecularly imprinted polymers (RGO/MIP)

D Limthin, P Leepheng, K Onlaor… - Japanese Journal of …, 2022 - iopscience.iop.org
In this study, to enhance the selectivity and sensitivity of salbutamol detection performed by
a carbon plate electrode, the electrode was modified using a novel molecularly imprinted …

[HTML][HTML] Metal oxide decorated carbon nanocomposite electrodes for propofol monitoring

DC Ferrier, J Kiely, R Luxton - Biosensors and Bioelectronics: X, 2022 - Elsevier
Despite the growing evidence of the benefits of total-intravenous anaesthesia using propofol
compared to conventional volatile-based anaesthesia, both in terms of environmental impact …

Handheld analyzer with on-chip molecularly-imprinted biosensors for electrical detection of propofol in plasma samples

CC Hong, CC Lin, CL Hong, ZX Lin, MH Chung… - Biosensors and …, 2016 - Elsevier
This paper proposes a novel handheld analyzer with disposable lab-on-a-chip technology
for the electrical detection of the anesthetic propofol in human plasma samples for clinical …