[引用][C] PP-036: IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCK DESPITE TERMINATION OF VENTRICULAR TACHYCARDIA BY ANTITACHYCARDIA …

S Okutucu, B Evranos, UN Karakulak… - International Journal of …, 2011 - infona.pl
PP-036: IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCK DESPITE TERMINATION
OF VENTRICULAR TACHYCARDIA BY ANTITACHYCARDIA PACING DURING CHARGING …

[HTML][HTML] Marked attenuation of shock burden by the use of antitachycardia pacing therapy in a patient with an implanted cardioverter-defibrillator

L Ganjehei, A Nazeri, A Massumi… - Texas Heart Institute …, 2012 - ncbi.nlm.nih.gov
A 76-year-old man was admitted to our institution for elective exchange of his implanted
cardioverter-defibrillator generator. Nine years earlier, he had been diagnosed with …

Implantable cardioverter-defibrillator discharges despite successful termination of ventricular tachycardia by antitachycardia pacing.

RT Ho - Pacing & Clinical Electrophysiology, 2009 - search.ebscohost.com
The article details the case of an 80-year-old man who has a Medtronic Entrust implantable
cardioverter-defibrillator (ICD), a history of symptomatic ventricular tachycardia, and …

Implantable Cardioverter‐Defibrillator Shock: Appropriate or Inappropriate?

MA Nault, WF McIntyre, CS Simpson… - Annals of …, 2010 - Wiley Online Library
A 76‐year‐old female with a single chamber implantable cardioverter‐defibrillator implanted
for secondary prevention was referred due to multiple discharges. The device was …

[PDF][PDF] An Appropriate Implantable Cardioverter-Defibrillator Shock Triggering Unusual Phenomenons.

MA Arias, A Puchol, T Colchero, M Pachon… - Pacing & Clinical …, 2010 - academia.edu
A 57-year-old man with ischemic cardiomyopathy and a history of ventricular tachycardia
(VT) 1 was admitted to the hospital after experiencing two consecutive implantable …

Inappropriate shock delivery by implantable defibrillators with dual chamber pacing during nonsustained ventricular tachycardia in patients with heart block

J Sra, M Akhtar - Pacing and Clinical Electrophysiology, 2000 - Wiley Online Library
Transvenous implantable cardioverter defibrillators (ICDs) have improved the management
of patients with ventricular tachycardia/ventricular fibrillation (VT/VF). 1–5 Many patients with …

Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy

JW Leitch, AM Gillis, DG Wyse, R Yee, GJ Klein… - Journal of the American …, 1991 - Elsevier
Implantable defibrillators reduce the risk of sudden death in patients with malignant
ventricular arrhythmias, but significant restriction in quality of life can occur as a result of …

Failure to deliver ICD shocks after a failed discharge despite redetection of rapid ventricular tachycardia? What is the cause?

JP Marenco - Pacing & Clinical Electrophysiology, 2013 - search.ebscohost.com
The article presents a case study of a 60-year-old man who was rushed to the emergency
room due to palpitations, light-headedness, and a single implantable cardioverter …

Implantable cardioverter defibrillator: Charge saver, not syncope saver!

D Chemello, A Subramanian, S Watkins, K Nair… - Canadian Journal of …, 2010 - Elsevier
In patients with an implantable cardioverter defibrillator, empirical antitachycardia
pacing/burst pacing (ATP) is associated with a significantly decreased rate of appropriate …

Implantable cardioverter-defibrillator shocks and nonsustained rapid ventricular rhythms

H Witteveen, P Stellingwerf, HF Groenveld - Netherlands Heart Journal, 2023 - Springer
The ECG (Fig. 1 in the question) shows sinus bradycardia and 8 fast ventricular pacing
spikes with ventricular capture. The chest X-ray depicts a normal position of the ventricular …