A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs
A Rodrigues, D Sawkey, FF Yin, Q Wu - Medical physics, 2015 - Wiley Online Library
Purpose: To develop a framework for accurate electron Monte Carlo dose calculation. In this
study, comprehensive validations of vendor provided electron beam phase space files for …
study, comprehensive validations of vendor provided electron beam phase space files for …
Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements
P Edimo, C Clermont, MG Kwato, S Vynckier - Physica Medica, 2009 - Elsevier
In the present work, Monte Carlo (MC) models of electron beams (energies 4, 12 and
18MeV) from an Elekta SL25 medical linear accelerator were simulated using …
18MeV) from an Elekta SL25 medical linear accelerator were simulated using …
Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC‐shaped fields
SAM Lloyd, IM Gagne, M Bazalova‐Carter… - Medical …, 2016 - Wiley Online Library
Purpose: This work evaluates Varian's electron phase–space sources for Monte Carlo
simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined …
simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined …
Monte Carlo modeling of electron beams from a NEPTUN 10PC medical linear accelerator
N Jabbari, B Hashemi-Malayeri - Nukleonika, 2009 - infona.pl
The Monte Carlo (MC) simulation of radiation transport is considered to be one of the most
accurate methods of radiation therapy dose calculation. With the rapid development of …
accurate methods of radiation therapy dose calculation. With the rapid development of …
Monte Carlo electron source model validation for an Elekta Precise linac
OA Ali, CA Willemse, W Shaw, FHJ O'Reilly… - Medical …, 2011 - Wiley Online Library
Purpose: Electron radiation therapy is used frequently for the treatment of skin cancers and
superficial tumors especially in the absence of kilovoltage treatment units. Head‐and‐neck …
superficial tumors especially in the absence of kilovoltage treatment units. Head‐and‐neck …
Monte Carlo commissioning of clinical electron beams using large field measurements
TP O'Shea, DL Sawkey, MJ Foley… - Physics in Medicine & …, 2010 - iopscience.iop.org
Monte Carlo simulation can accurately calculate electron fluence at the patient surface and
the resultant dose deposition if the initial source electron beam and linear accelerator …
the resultant dose deposition if the initial source electron beam and linear accelerator …
Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6–20 MeV)
F Verhaegen, C Mubata, J Pettingell… - Medical …, 2001 - Wiley Online Library
Monte Carlo (MC) techniques can be used to build a simulation model of an electron
accelerator to calculate output factors for electron fields. This can be useful during …
accelerator to calculate output factors for electron fields. This can be useful during …
Accurate characterization of Monte Carlo calculated electron beams for radiotherapy
Monte Carlo studies of dose distributions in patients treated with radiotherapy electron
beams would benefit from generalized models of clinical beams if such models introduce …
beams would benefit from generalized models of clinical beams if such models introduce …
Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: dose and IAEA‐compliant phase space calculations
M Constantin, J Perl, T LoSasso, A Salop… - Medical …, 2011 - Wiley Online Library
Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian
TrueBeam treatment head geometry imported from cad (computer aided design) without …
TrueBeam treatment head geometry imported from cad (computer aided design) without …
Characteristics of elliptical sources in BEAMnrc Monte Carlo system: Implementation and application
S Kim - Medical physics, 2009 - Wiley Online Library
Recently, several papers noticed that the electron focal spot of a linear accelerator (linac)
could be elliptical which would cause dosimetric discrepancies between measurements and …
could be elliptical which would cause dosimetric discrepancies between measurements and …