Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Continuous monitoring of the central blood pressure waveform from deeply embedded
vessels such as the carotid artery and jugular vein has clinical value for the prediction of all …
vessels such as the carotid artery and jugular vein has clinical value for the prediction of all …
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Stretchable wearable devices for the continuous monitoring of physiological signals from
deep tissues are constrained by the depth of signal penetration and by difficulties in …
deep tissues are constrained by the depth of signal penetration and by difficulties in …
A novel art of continuous noninvasive blood pressure measurement
J Fortin, DE Rogge, C Fellner, D Flotzinger… - Nature …, 2021 - nature.com
Wearable sensors to continuously measure blood pressure and derived cardiovascular
variables have the potential to revolutionize patient monitoring. Current wearable methods …
variables have the potential to revolutionize patient monitoring. Current wearable methods …
Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance device
Smart rings provide unique opportunities for continuous physiological measurement. They
are easy to wear, provide little burden in comparison to other smart wearables, are suitable …
are easy to wear, provide little burden in comparison to other smart wearables, are suitable …
SeismoWatch: wearable cuffless blood pressure monitoring using pulse transit time
AM Carek, J Conant, A Joshi, H Kang… - Proceedings of the ACM …, 2017 - dl.acm.org
The current norm for measuring blood pressure (BP) at home is using an automated BP cuff
based on oscillometry. Despite providing a viable and familiar method of tracking BP at …
based on oscillometry. Despite providing a viable and familiar method of tracking BP at …
A comparison of wearable tonometry, photoplethysmography, and electrocardiography for cuffless measurement of blood pressure in an ambulatory setting
R Mieloszyk, H Twede, J Lester… - IEEE Journal of …, 2022 - ieeexplore.ieee.org
Objective: While non-invasive, cuffless blood pressure (BP) measurement has demonstrated
relevancy in controlled environments, ambulatory measurement is important for …
relevancy in controlled environments, ambulatory measurement is important for …
Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial
for preventing and diagnosing hypertension related diseases. However, current continuous …
for preventing and diagnosing hypertension related diseases. However, current continuous …
Arteriosclerosis assessment based on single‐point fingertip pulse monitoring using a wearable iontronic sensor
Arteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is
the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is …
the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is …
Cuffless blood pressure measurement
R Mukkamala, GS Stergiou… - Annual Review of …, 2022 - annualreviews.org
Cuffless blood pressure (BP) measurement has become a popular field due to clinical need
and technological opportunity. However, no method has been broadly accepted hitherto …
and technological opportunity. However, no method has been broadly accepted hitherto …
Multi-wavelength photoplethysmography enabling continuous blood pressure measurement with compact wearable electronics
Objective: To fight the “silent killer” hypertension, continuous blood pressure (BP) monitoring
has been one of the most desired functions in wearable electronics. However, current BP …
has been one of the most desired functions in wearable electronics. However, current BP …