Efficiency correction factors of an ACCUSCAN whole-body counter due to the biodistribution of 134Cs, 137Cs and 60Co

J Bento, S Barros, P Teles, P Vaz… - Radiation protection …, 2013 - academic.oup.com
The efficiency calibration of whole-body counters (WBCs) for monitoring of internal
contaminations is usually performed with anthropomorphic physical phantoms assuming …

Comparison of computational phantoms and investigation of the effect of biodistribution on activity estimations

P Cartemo, J Nilsson, M Isaksson… - Radiation Protection …, 2016 - academic.oup.com
A comparison was made between two computational phantoms, modelled from the unified
phantom UPh-08 T, for whole-body counting applications. One of these was further …

Monte Carlo calculation of whole body counter efficiency factors for different computational phantoms

CVG Ferreira, JS Piedade, MRD Prado… - Applied Radiation and …, 2023 - Elsevier
Individual monitoring can provide an estimate of the radioactivity present in the body of the
exposed individuals. Periodic monitoring of occupationally exposed individuals is of great …

Theoretical assessment of whole body counting performances using numerical phantoms of different gender and sizes

O Marzocchi, B Breustedt, D Mostacci… - Radiation protection …, 2011 - academic.oup.com
A goal of whole body counting (WBC) is the estimation of the total body burden of
radionuclides disregarding the actual position within the body. To achieve the goal, the …

Study of the influence of radionuclide biokinetics on the efficiency of in vivo counting using Monte Carlo simulation

S Lamart, E Blanchardon, A Molokanov… - Health …, 2009 - journals.lww.com
To improve calibration methods of in vivo counting, our laboratory has developed a
computer tool to model internal contamination and assess in vivo activity and corresponding …

Efficiency calibration of a whole-body-counting measurement setup using a modular physical phantom

AL Lebacq, M Bruggeman… - Radiation protection …, 2011 - academic.oup.com
Physical phantoms are used at whole-body-counting (WBC) laboratories to calibrate
detector systems for in vivo monitoring of radionuclides internally deposited in the body …

An intercomparison of counting efficiency and the performance of two whole-body counters according to the type of phantom

M Pak, J Yoo, WH Ha, YW Jin - Journal of Radiation Protection and …, 2016 - koreascience.kr
Background: Whole-body counters are widely used to evaluate internal contamination of the
internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic …

Application of voxel phantoms in whole-body counting for the validation of calibration phantoms and the assessment of uncertainties

L Carlan, P Roch, E Blanchardon… - Radiation protection …, 2007 - academic.oup.com
This article is dedicated to the application of voxel phantoms in whole-body counting
calibration. The first study was performed to validate this approach using IGOR, a physical …

Monte Carlo simulation of a whole-body counter using IGOR phantoms

FO Bochud, JP Laedermann, S Baechler… - Radiation protection …, 2014 - academic.oup.com
Whole-body counting is a technique of choice for assessing the intake of gamma-emitting
radionuclides. An appropriate calibration is necessary, which is done either by experimental …

Automatic application of ICRP biokinetic models in voxel phantoms for in vivo counting and internal dose assessment

S Lamart, L De Carlan, E Blanchardon… - Radiation protection …, 2007 - academic.oup.com
As part of the improvement of calibration techniques of in vivo counting, the Laboratory of
Internal Dose Assessment of the Institute of Radiological Protection and Nuclear Safety has …