Effects of a cervical disc prosthesis on maintaining sagittal alignment of the functional spinal unit and overall sagittal balance of the cervical spine

SW Kim, JH Shin, JJ Arbatin, MS Park, YK Chung… - European Spine …, 2008 - Springer
The object of this study is to review the early clinical results and radiographic outcomes
following insertion of the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek …

Effects of a cervical disc prosthesis on segmental and cervical spine alignment

GE Pickett, DK Mitsis, LH Sekhon, WR Sears… - Neurosurgical …, 2004 - thejns.org
Object Cervical arthroplasty offers the promise of maintaining motion of the functional spinal
unit (FSU) after anterior cervical discectomy. The impact of cervical arthroplasty on sagittal …

A clinical analysis of 4-and 6-year follow-up results after cervical disc replacement surgery using the Bryan Cervical Disc Prosthesis

J Goffin, J Van Loon, F Van Calenbergh… - Journal of Neurosurgery …, 2010 - thejns.org
Object In this study, long-term results are presented from clinical studies of the Bryan
Cervical Disc Prosthesis at University Hospital Gasthuisberg in Leuven, Belgium. A total of …

10-year follow-up after implantation of the Bryan Cervical Disc Prosthesis

J Dejaegher, J Walraevens, J van Loon… - European Spine …, 2017 - Springer
Purpose Cervical arthroplasty is being used as an alternative for cervical fusion, but long-
term follow-up results have rarely been reported. In this paper, we present 10-year follow-up …

Segmental malalignment with the Bryan cervical disc prosthesis—contributing factors

WR Sears, N Duggal, LH Sekhon… - Clinical Spine …, 2007 - journals.lww.com
Part 1 of the current study found that use of the Bryan Cervical Disc prosthesis resulted in a
median loss of 2 degrees in functional spinal unit (FSU) lordosis when compared with …

Early and intermediate follow-up results after treatment of degenerative disc disease with the Bryan cervical disc prosthesis: single-and multiple-level

S Yang, X Wu, Y Hu, J Li, G Liu, W Xu, C Yang, S Ye - Spine, 2008 - journals.lww.com
Study Design. Our clinical study design was prospective, concurrently enrolled and single-
center trial of the new functional intervertebral cervical disc prosthesis (Medtronic Sofamor …

Intermediate follow-up after treatment of degenerative disc disease with the Bryan Cervical Disc Prosthesis: single-level and bi-level

J Goffin, F Van Calenbergh, J van Loon, A Casey… - Spine, 2003 - journals.lww.com
Study Design. Prospective, concurrently enrolled, multicenter trials of the Bryan Cervical
Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN) were conducted for the treatment …

Comparison of radiographic changes after ACDF versus Bryan disc arthroplasty in single and bi-level cases

SW Kim, MA Limson, SB Kim, JJF Arbatin… - European spine …, 2009 - Springer
The object of this study is to compare radiographic outcomes of anterior cervical
decompression and fusion (ACDF) versus cervical disc replacement using the Bryan …

Intervertebral disc replacement for cervical degenerative disease – clinical results and functional outcome at two years in patients implanted with the Bryan® cervical …

V Heidecke, W Burkert, M Brucke, NG Rainov - Acta neurochirurgica, 2008 - Springer
Background. This is a prospective study of patients with degenerative cervical disease who
underwent ventral discectomy and disc replacement with the Bryan® cervical disc …

Fusion versus Bryan Cervical Disc in two-level cervical disc disease: a prospective, randomised study

L Cheng, L Nie, L Zhang, Y Hou - International orthopaedics, 2009 - Springer
In this prospective study, our aim was to compare the functional results and radiographic
outcomes of fusion and Bryan Cervical Disc replacement in the treatment of two-level …