Anatomically and mechanically accurate scala tympani model for electrode insertion studies

A Starovoyt, E Shaheen, T Putzeys, G Kerckhofs… - Hearing Research, 2023 - Elsevier
The risk of insertion trauma in cochlear implantation is determined by the interplay between
individual cochlear anatomy and electrode insertion mechanics. Whereas patient anatomy …

[HTML][HTML] Fabrication of human anatomy-based scala tympani models with a hydrophilic coating for cochlear implant insertion experiments

P Aebischer, M Caversaccio, W Wimmer - Hearing research, 2021 - Elsevier
Electrode array insertion into the inner ear is a critical step in cochlear implantation, and
artificial scala tympani models can be a valuable tool for studying the dynamics of this …

Analysis of intersubject variations in intracochlear and middle ear surface anatomy for cochlear implantation

S Pelosi, JH Noble, BM Dawant… - Otology & …, 2013 - journals.lww.com
Background Recent publications suggest that both atraumatic electrode insertion and
electrode location within the scala tympani can affect auditory performance after CI …

Impact of anatomical variations on insertion forces

S Hügl, T Blum, T Lenarz, O Majdani… - Current Directions in …, 2018 - degruyter.com
The choice of a cochlear implant electrode carrier for the individual patient is influenced by
cochlear size, as this parameter has an impact on the risk of scala dislocations. Therefore …

Morphometric analysis and linear measurements of the scala tympani and implications in cochlear implant electrodes

RJT Fujiwara, G Ishiyama, IA Lopez… - Otology & …, 2023 - journals.lww.com
Background Previous investigations in scala tympani dimensions have used microcomputed
tomography or casting modalities, which cannot be correlated directly with microanatomy …

Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model

TS Rau, A Hussong, M Leinung, T Lenarz… - International journal of …, 2010 - Springer
Purpose As a substantial part of our concept of a minimally invasive cochlear implant (CI)
surgery, we developed an automated insertion tool. Studies on an artificial scala tympani …

[PDF][PDF] Uncovering Vulnerable Phases in Cochlear Implant Electrode Array Insertion: Insights from an In Vitro Model

P Aebischer, S Weder, M Vischer… - Otology & …, 2023 - journals.lww.com
Objectives The aim of this study is to improve our understanding of the mechanics involved
in the insertion of lateral wall cochlear implant electrode arrays. Design A series of 30 …

Real-time haptic modeling and simulation for prosthetic insertion

CA Todd, F Naghdy - 2011 - ro.uow.edu.au
In this work a surgical simulator is produced which enables a training otologist to conduct a
virtual, real-time prosthetic insertion. The simulator provides the Ear, Nose and Throat …

Scala-tympani phantom with cochleostomy and round-window openings for cochlear-implant insertion experiments

L Leon, MS Cavilla, MB Doran… - Journal of …, 2014 - asmedigitalcollection.asme.org
Experiments with scala-tympani (ST) phantoms are used to evaluate new electrode arrays
and cochlear-implant insertion techniques. To date, phantoms have not accounted for …

Variability of an ideal insertion vector for cochlear implantation

HA Breinbauer, M Praetorius - Otology & Neurotology, 2015 - journals.lww.com
Background During cochlear implantation through a cochleostomy or round window
approach, the angle or vector of insertion after the first entry point seems to be related to …