Sideband harmonic instability of paralleled inverters with asynchronous carriers

D Yang, X Wang, F Blaabjerg - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Paralleled inverters with asynchronous carriers are increasingly emerging into renewable
power plants and other power-electronic-based power systems. The sideband harmonics …

[HTML][HTML] Dc-link current harmonic mitigation via phase-shifting of carrier waves in paralleled inverter systems

S Baburajan, H Wang, D Kumar, Q Wang, F Blaabjerg - Energies, 2021 - mdpi.com
DC-connected parallel inverter systems are gaining popularity in industrial applications.
However, such parallel systems generate excess current ripple (harmonics) at the DC-link …

State-space-based harmonic stability analysis for paralleled grid-connected inverters

Y Wang, X Wang, Z Chen… - IECON 2016-42nd …, 2016 - ieeexplore.ieee.org
This paper addresses a state-space-based harmonic stability analysis of paralleled grid-
connected inverters system. A small signal model of individual inverter is developed, where …

Harmonic suppression and stability enhancement for parallel multiple grid-connected inverters based on passive inverter output impedance

Q Qian, S Xie, L Huang, J Xu, Z Zhang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, the inverter output impedance is passivized for solving the harmonic and the
stability problems in the multiparallel inverters. The harmonics are easily aroused because …

Harmonic stability assessment for multiparalleled, grid-connected inverters

C Yoon, H Bai, RN Beres, X Wang… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
This paper investigates the harmonic interactions of current controllers in multiparalleled
grid-connected inverters. Potential harmonic instability phenomenon, which features …

Grid-synchronization modeling and its stability analysis for multi-paralleled three-phase inverter systems

D Dong, B Wen, P Mattavelli… - 2013 Twenty-Eighth …, 2013 - ieeexplore.ieee.org
Synchronization instability issue and the corresponding low-frequency power oscillation
phenomenon between synchronous generators were already found in electric power …

[HTML][HTML] Analysis and mitigation of harmonic resonances in multi–parallel grid–connected inverters: A review

R Ali, T O'Donnell - Energies, 2022 - mdpi.com
With the move towards decarbonization of the energy system and increased use of
renewable generation, the number of power electronics converter interfaced resources …

Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters

T Messo, J Jokipii, A Aapro… - 2014 16th European …, 2014 - ieeexplore.ieee.org
The amount of grid-connected inverters has been growing steadily over the past decade due
to increase in renewable power generation. These inverters have been reported to degrade …

A harmonic mitigation technique for multi-parallel grid-connected inverters in distribution networks

KG Khajeh, D Solatialkaran, F Zare… - … on Power Delivery, 2021 - ieeexplore.ieee.org
Different harmonic mitigation techniques have been utilized in grid-connected inverters to
suppress the effect of grid voltage distortion on the output current of these inverters. In …

Modeling and analysis of harmonic stability in an AC power-electronics-based power system

X Wang, F Blaabjerg, W Wu - IEEE transactions on power …, 2014 - ieeexplore.ieee.org
This paper addresses the harmonic stability caused by the interactions among the wideband
control of power converters and passive components in an ac power-electronics-based …