Cochlear implantation with a novel long straight electrode: the insertion results evaluated by imaging and histology in human temporal bones

S Sipari, M Iso-Mustajärvi, H Matikka… - Otology & …, 2018 - journals.lww.com
Background: The main focuses of modern cochlear implant surgery are to prevent damage
to the intracochlear structures and to preserve residual hearing. This is often achievable with …

Assessment of intracochlear trauma caused by the insertion of a new straight research array

P Mukherjee, H Uzun-Coruhlu, CC Wong… - Cochlear Implants …, 2012 - Taylor & Francis
Objective To assess the degree of intracochlear trauma using the Cochlear™ Straight
Research Array (SRA). This electrode has recently been released by Cochlear™ on the …

Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones

A Dietz, M Iso-Mustajärvi, S Sipari, J Tervaniemi… - European Archives of …, 2018 - Springer
Purpose To evaluate the insertion characteristics and trauma of a new slim lateral wall
electrode (SlimJ) in human temporal bones (TB). Methods Pre-and postoperative …

Atraumaticity study of 2 cochlear implant electrode arrays

M Manrique, S Picciafuoco, R Manrique… - Otology & …, 2014 - journals.lww.com
Background Atraumatic surgery and electrode arrays are current topics in otologic surgery.
The preservation of cochlear anatomy and its functions is a priority and morphologic …

Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study

O Adunka, MH Unkelbach, M Mack… - Acta oto …, 2004 - Taylor & Francis
Objective To evaluate cochlear implant trauma to intracochlear structures when inserting the
electrode via the round window membrane. Material and methods Eight fresh human …

Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation–fact or fantasy?

OF Adunka, HC Pillsbury, J Kiefer - Acta Oto-Laryngologica, 2006 - Taylor & Francis
Conclusions. Except for basal cochlear traumatization, all specimens implanted into scala
tympani showed atraumatic insertion properties and good perimodiolar electrode …

First experience with a new thin lateral wall electrode in human temporal bones

T Lenarz, E Avci, D Gazibegovic… - Otology & …, 2019 - journals.lww.com
Methods: Ten fresh-frozen TBs were implanted with the SlimJ electrode array via the round
window. The electrode array is 23 mm long, with a cross-section varying from 0.25× 0.55 mm …

The new mid-scala electrode array: a radiologic and histologic study in human temporal bones

F Hassepass, S Bulla, W Maier, R Laszig… - Otology & …, 2014 - journals.lww.com
Background Modern cochlear implant surgery aims for a safe intracochlear placement of
electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) …

Cone beam computed tomography and histological evaluations of a straight electrode array positioning in temporal bones

I Mosnier, C Célérier, JL Bensimon… - Acta Oto …, 2017 - Taylor & Francis
Conclusion: CBCT allows a precise evaluation of the dimensions and of the shape of the
cochlear duct that is of primary importance for the choice of the length and the design of the …

Preservation of basal inner ear structures in cochlear implantation

O Adunka, W Gstoettner, M Hambek, MH Unkelbach… - Orl, 2005 - karger.com
The aim of this report was to examine basal trauma in implanted human temporal bones and
discuss modified approaches to the basal cochlear turn to avoid destruction of basal …