Diagnostic performance of the IMMY cryptococcal antigen lateral flow assay on serum and cerebrospinal fluid for diagnosis of cryptococcosis in HIV-negative patients …

C Macrae, J Ellis, SH Keddie, J Falconer… - BMC infectious …, 2023 - Springer
Background The incidence of cryptococcosis amongst HIV-negative persons is increasing.
Whilst the excellent performance of the CrAg testing in people living with HIV is well …

Evaluation of the Dynamiker cryptococcal antigen lateral flow assay for the diagnosis of HIV-associated cryptococcosis

R Kwizera, D Omali, K Tadeo, J Kasibante… - Journal of clinical …, 2021 - Am Soc Microbiol
Cryptococcal meningitis is a leading cause of meningitis in sub-Saharan Africa. Given the
need for rapid point-of-care testing, we evaluated the diagnostic performance of the …

Evaluation of a new cryptococcal antigen lateral flow immunoassay in serum, cerebrospinal fluid and urine for the diagnosis of cryptococcosis: a meta-analysis and …

HR Huang, LC Fan, B Rajbanshi, JF Xu - PLoS One, 2015 - journals.plos.org
Background A new lateral flow immunoassay (LFA) for the detection of cryptococcal antigen
was developed. Objective We aimed to systematically review all relevant studies to evaluate …

Evaluation of fingerstick cryptococcal antigen lateral flow assay in HIV-infected persons: a diagnostic accuracy study

DA Williams, T Kiiza, R Kwizera… - Clinical Infectious …, 2015 - academic.oup.com
Background. Cryptococcus neoformans is the most common cause of adult meningitis in sub-
Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified …

Validation of clinic-based cryptococcal antigen lateral flow assay screening in HIV-infected adults in South Africa

PK Drain, T Hong, M Krows, S Govere, H Thulare… - Scientific reports, 2019 - nature.com
Since rapid cryptococcal antigen lateral flow assays (CrAg LFA) may expedite treatment of
HIV-associated cryptococcal infections, we sought to validate clinic-based CrAg LFA testing …

The cryptococcal antigen lateral flow assay: A point-of-care diagnostic at an opportune time

MW Tang, KV Clemons, DA Katzenstein… - Critical reviews in …, 2016 - Taylor & Francis
Cryptococcal meningitis is a devastating HIV-related opportunistic infection, affecting nearly
1 million individuals and causing over 500 000 deaths each year. The burden of disease is …

[HTML][HTML] Diagnosis of cryptococcosis and prevention of cryptococcal meningitis using a novel point-of-care lateral flow assay

A Dhana - Case Reports in Medicine, 2013 - hindawi.com
Despite access to antiretroviral therapy, mortality from cryptococcal meningitis (CM) is high
among persons with advanced HIV infection in sub-Saharan Africa. Cryptococcal antigen …

Evaluation of a point-of-care immunoassay test kit 'StrongStep'for cryptococcal antigen detection

E Mpoza, L Mukaremera, DA Kundura, A Akampurira… - PLoS …, 2018 - journals.plos.org
Background HIV-associated cryptococcal meningitis is the leading cause of adult meningitis
in Sub-Saharan Africa, accounting for 15%–20% of AIDS-attributable mortality. The …

Brief report: point of care cryptococcal antigen screening: pipetting finger-prick blood improves performance of immunomycologics lateral flow assay

RM Wake, JN Jarvis, TS Harrison… - JAIDS Journal of …, 2018 - journals.lww.com
Background: Cryptococcal antigen (CrAg) screening at the point of care could improve
cryptococcal meningitis prevention where laboratory resources are limited. We evaluated …

Diagnostic accuracy of the Biosynex CryptoPS cryptococcal antigen semiquantitative lateral flow assay in patients with advanced HIV disease

MW Tenforde, T Boyer-Chammard… - Journal of Clinical …, 2020 - Am Soc Microbiol
High cryptococcal antigen (CrAg) titers in blood are associated with subclinical meningitis
and mortality in CrAg-positive individuals with advanced HIV disease (AHD). We evaluated …