Brain Tissue and Sagittal Sinus pO2 Measurements Using the Lifetimes of Oxygen-Quenched Luminescence of a Ruthenium Compound

CI Nwaigwe, MA Roche, O Grinberg… - Oxygen Transport to Tissue …, 2003 - Springer
The study was done to assess the performance of a system that measures the partial
pressures of oxygen (pO 2) from the lifetimes of oxygen-quenched luminescence of …

Measurement of Arterial, Venous, and Interstitial pO2 during Acute Hypoxia in Rat Brain using a Time-Resolved Luminescence-Based Oxygen Sensor

JF Dunn, CI Nwaigwe, M Roche - Oxygen Transport to Tissue XXI, 1999 - Springer
This is the first publication using a fiber optic" optode" and a luminescence based p02
detection method for assessing neural tissue oxygenation. The system was used to …

In vivo measurement of tissue oxygenation by time-resolved luminescence spectroscopy: advantageous properties of dichlorotris(1, 10-phenanthroline)-ruthenium(II) …

V Huntosova, S Gay… - … of biomedical optics, 2014 - spiedigitallibrary.org
Measuring tissue oxygenation in vivo is of interest in fundamental biological as well as
medical applications. One minimally invasive approach to assess the oxygen partial …

A method for measuring brain partial pressure of oxygen in unanesthetized unrestrained subjects: the effect of acute and chronic hypoxia on brain tissue PO2

E Ortiz-Prado, S Natah, S Srinivasan… - Journal of neuroscience …, 2010 - Elsevier
The level of tissue oxygenation provides information related to the balance between oxygen
delivery, oxygen utilization, tissue reactivity and morphology during physiological conditions …

Cerebral oxygenation of the cortex and striatum following normobaric hyperoxia and mild hypoxia in rats by EPR oximetry using multi-probe implantable resonators

H Hou, H Li, R Dong, S Mupparaju, N Khan… - Oxygen transport to …, 2011 - Springer
Multi-site electron paramagnetic resonance (EPR) oximetry, using multiprobe implantable
resonators, was used to measure the partial pressure of oxygen (pO 2) in the brains of rats …

First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors

T Jarm, H Lešničar, G Serša… - Radiology and Oncology, 2001 - radioloncol.com
Background. The purpose of this preliminary study was to evaluate a novel luminescence-
based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen …

Brain Tissue PO2 Measurement During Normoxia and Hypoxia Using Two-Photon Phosphorescence Lifetime Microscopy

K Xu, DA Boas, S Sakadžić, JC LaManna - Oxygen Transport to Tissue …, 2017 - Springer
Key to the understanding of the principles of physiological and structural acclimatization to
changes in the balance between energy supply (represented by substrate and oxygen …

O2 Flux Optode: A New Sensing Principle to Determine the Oxygen Flux and Other Gas Diffusions

DW Lübbers, T Köster, GA Holst - Oxygen Transport to Tissue XVII, 1996 - Springer
By applying a transparent test membrane of defined diffusion properties between two layers
of optical chemical oxygen sensors, O 2 optodes, the measurement of oxygen diffusion, the …

Simultaneous measurement of rat brain cortex PtO2 using EPR oximetry and a fluorescence fiber-optic sensor during normoxia and hyperoxia

JA O'Hara, H Hou, E Demidenko… - Physiological …, 2005 - iopscience.iop.org
Electron paramagnetic resonance (EPR) oximetry is a promising, relatively non-invasive
method of monitoring tissue partial pressure of oxygen (PtO 2) that has proven useful in …

Measurements of tumor tissue oxygen tension using a time-resolved luminescence-based optical oxylite probe: comparison with a paired survival assay

M Urano, Y Chen, J Humm, JA Koutcher… - Radiation …, 2002 - meridian.allenpress.com
Abstract Urano, M., Chen, Y., Humm, J., Koutcher, J., Zanzonico, P. and Ling, C.
Measurements of Tumor Tissue Oxygen Tension Using a Time-Resolved Luminescence …