Seismic Response of Base-isolated Dual-system Reinforced Concrete Buildings at a Near-fault Site

M Seify Asghshahr, S Rafiei - Amirkabir Journal of Civil Engineering, 2022 - ceej.aut.ac.ir
In high-rise reinforced concrete buildings, using base-isolating systems can increase the
response of the structure. To overcome this problem, it is suggested to increase the stiffness …

[HTML][HTML] Effect of base isolator on the structural response of reinforced concrete multistoried building under seismic loads

Z Tafheem, TA Arafat, A Chowdhury… - Journal of Civil …, 2017 - publisher.unimas.my
This study investigates the effect of base isolator on the structural responses of multistoried
reinforced concrete building under time history earthquake loading. In the present study, six …

Dynamic responses of the base-fixed and isolated building frames under far-and near-fault earthquakes

HR Tavakoli, F Naghavi, AR Goltabar - Arabian Journal for Science and …, 2014 - Springer
In this study, dynamic responses of the multistory base-isolated and base-fixed buildings are
investigated under near-and far-fault ground motions. Lead–rubber isolation bearing (LRB) …

Seismic response evaluation of base-isolated reinforced concrete buildings under bidirectional excitation

S Bhagat, AC Wijeyewickrema - Earthquake Engineering and Engineering …, 2017 - Springer
This paper reports on an investigation of the seismic response of base-isolated reinforced
concrete buildings, which considers various isolation system parameters under bidirectional …

Soft-story effects on the behavior of fixed-base and LRB base-isolated reinforced concrete buildings

MA Komur - Arabian Journal for Science and Engineering, 2016 - Springer
In Turkey, the entry stories of reinforced concrete (RC) structures are usually used for
commercial purposes because they are slightly higher than other stories. Therefore, these …

[PDF][PDF] Seismic response of fixed-base and LRB base-isolated RC frame systems under NF and FF excitations

MA Kömür, İÖ Deneme, R Oruç - J. Struct. Eng, 2019 - goldenlightpublish.com
Seismic isolation systems can be used in new structures to reduce the negative effects of the
earthquake on the building. The lead rubber bearing (LRB) is one of the most commonly …

Effects of Base Isolation and Infill Panels on the Nonlinear Time History Analysis of Reinforced Concrete Building

HJ Mohamad, MN Mahmood - Key Engineering Materials, 2021 - Trans Tech Publ
This paper presents the predicted results of nonlinear time history analysis of 11 storey (G+
10) Reinforced Concrete (RC) residential building under the effects of a strong earthquake …

Seismic performance comparison of fixed and base-isolated models

E Ozer, M Inel, BT Cayci - Iranian Journal of Science and Technology …, 2023 - Springer
This study aims to compare seismic response of fixed-base and most preferred base
isolation models including lead rubber bearing (LRB), curved surface friction bearing (FPS) …

[PDF][PDF] Seismic Analysis of Multi Storey RC Buildings supported on Single and Combined Base Isolation Systems

AV Nithin, R Jayalekshmi - vol, 2017 - researchgate.net
Base Isolation is an earthquake mitigation technique where seismic demand on the building
is reduced rather than increasing the earthquake resistance capacity of the building. Base …

[PDF][PDF] Influence of Near-Fault Ground Motions and Seismic Pounding on The Response of Base-Isolated Reinforced Concrete Buildings

DR Pant, AC Wijeyewickrema - Joint Conference Proceedings 9th …, 2012 - academia.edu
This paper investigates the effects of near-fault ground motions and seismic pounding on the
response of a code-designed 4-story base-isolated reinforced concrete (RC) building. Three …