Testing the retention of attachments for implant overdentures–validation of an original force measurement system

O Fromentin, C Lassauzay, S Abi Nader… - Journal of oral …, 2010 - Wiley Online Library
The aim of this study was to validate an original portable device to measure attachment
retention of implant overdentures both in the lab and in clinical settings. The device was built …

Comparative study of four retentive anchor systems for implant supported overdentures–retention force changes

S Bayer, D Steinheuser, M Grüner, L Keilig… - …, 2009 - Wiley Online Library
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the
function of complete dentures. This study evaluated the retention force changes of different …

Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components

LC da Fontoura Frasca, PRC Mattia, DM Botega… - Implant …, 2014 - journals.lww.com
Purpose: To compare retention forces of 3 overdenture attachment systems with metal and
plastic components. Materials and Methods: Four samples of each system evaluated (Ball …

Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments

N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …

Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems

M Kobayashi, M Srinivasan, P Ammann… - Clinical oral implants …, 2014 - Wiley Online Library
Background Mandibular two‐implant‐retained overdentures were suggested as first choice
of treatment for edentulous mandibles. However, wear of the attachments may reduce their …

Comparison of retention and release periods for implant overdenture attachments.

VC Petropoulos, W Smith… - International Journal of …, 1997 - search.ebscohost.com
The aim of this study was to compare the retention and release periods of the Nobel Biocare
bar and clip (NBC), Nobel Biocare ball (NB), Zest anchor (ZA), Zest magnet (ZM), and …

In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations

S Maniewicz, I Badoud, FR Herrmann… - Clinical oral implants …, 2020 - Wiley Online Library
Objectives This in vitro study aimed to compare changes in retentive force due to cyclic
dislodging of three novel un‐splinted attachments. Materials and Methods Experimental …

Maximum dislodging forces of implant overdenture stud attachments.

VC Petropoulos, W Smith - International Journal of Oral & …, 2002 - search.ebscohost.com
Purpose: The aim of this study was to compare the retention and stability of the Nobel
Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA) …

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

T Shastry, NM Anupama, S Shetty… - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this in vitro study was to compare the change in the retentive force and
removal torque of three attachment systems during simulation of insertion-removal cycles …

Methodology for measuring the in vitro seating and unseating forces of prefabricated attachment systems used to retain implant overdentures

A Fakhry, SC Tan, AD Heiner… - … Implant, Esthetic and …, 2010 - Wiley Online Library
Purpose: The purpose of this in vitro investigation was to measure the forces generated
during the continuous seating and unseating of prefabricated attachment systems used to …