Method evaluation study of a new generation of vitamin D assays

D Enko, G Kriegshäuser, R Stolba, E Worf… - Biochemia …, 2015 - hrcak.srce.hr
Sažetak Introduction: Recently several diagnostic manufacturers have launched new 25-
hydroxy-vitamin D (25 [OH] D) assays, which are aligned to the National Institute of …

Comparison of four current 25-hydroxyvitamin D assays

HW Moon, JH Cho, M Hur, J Song, GY Oh, CM Park… - Clinical …, 2012 - Elsevier
OBJECTIVES: The performance of recently developed vitamin D total assays (ADVIA
Centaur and Elecsys) was compared to that of liquid chromatography–tandem mass …

State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography–tandem mass spectrometry methods

CJL Farrell, S Martin, B McWhinney, I Straub… - Clinical …, 2012 - academic.oup.com
BACKGROUND Vitamin D testing is increasing worldwide. Recently several diagnostic
manufacturers including Abbott and Siemens have launched automated 25-hydroxy vitamin …

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

FE Kocak, B Ozturk, OO Isiklar, O Genc, A Unlu… - Biochemia …, 2015 - hrcak.srce.hr
Sažetak Introduction: Total 25-hydroxyvitamin D [25 (OH) D] is the most reliable indicator of
vitamin D status. In this study, we compared two automated immunoassay methods, the …

Performance evaluation of two immunoassays for 25-hydroxyvitamin D

L Li, Q Zeng, J Yuan, Z Xie - Journal of Clinical Biochemistry and …, 2016 - jstage.jst.go.jp
[25 (OH) D] have been improved recently, relatively large differences are still seen between
results of 25 (OH) D measured by immuno assays and by liquid chromatography tandem …

Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) …

L Saleh, D Mueller, A von Eckardstein - Clinical Chemistry and …, 2016 - degruyter.com
Background: We evaluated the analytical and clinical performance of the new Lumipulse® G
25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem …

Influence of Vitamin D2 Percentage on Accuracy of 4 Commercial Total 25-Hydroxyvitamin D Assays

I Shu, S Pina-Oviedo, G Quiroga-Garza… - Clinical …, 2013 - academic.oup.com
25-Hydroxyvitamin D (25-OHD) 1 is the most appropriate marker for monitoring vitamin D
storage status. The 2 major forms of 25-OH-D [25-OH-D2 (D2) and 25-OH-D3 (D3)], differ …

Measurement of circulating 25‐hydroxy vitamin D using three commercial enzyme‐linked immunosorbent assay kits with comparison to liquid chromatography …

CS He, M Gleeson, WD Fraser - … Scholarly Research Notices, 2013 - Wiley Online Library
Aim. The purpose of this study was to compare the accuracy and clinical implications of
three commercial enzyme‐linked immunosorbent assay (ELISA) kits (Eagle Biosciences …

Agreement of seven 25-hydroxy vitamin D3 immunoassays and three high performance liquid chromatography methods with liquid chromatography tandem mass …

D Denimal, V Ducros, T Dupré, B Dousset… - Clinical Chemistry and …, 2014 - degruyter.com
Background: Several recent studies have shown some discrepancies between 25-
hydroxyvitamin D [25 (OH) D] assay methods, despite some improvement in the past few …

[HTML][HTML] Efficacy of two vitamin D immunoassays to detect 25-OH vitamin D2 and D3

E Garnett, J Li, D Rajapakshe, E Tam, QH Meng… - Practical laboratory …, 2019 - Elsevier
Abstract Objectives Assessment of Vitamin D status by measurement of 25-Hydroxyvitamin
D (25-OH-D) is widely performed by immunoassay. Yet, the ability of these assays to detect …