MLC parameters from static fields to VMAT plans: an evaluation in a RT-dedicated MC environment (PRIMO)

L Paganini, G Reggiori, A Stravato, V Palumbo… - Radiation …, 2019 - Springer
Background PRIMO is a graphical environment based on PENELOPE Monte Carlo (MC)
simulation of radiotherapy beams able to compute dose distribution in patients, from plans …

PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs

M Hermida–López, D Sánchez–Artuñedo… - Radiation …, 2018 - Springer
Background The software PRIMO for the Monte Carlo simulation of radiotherapy linacs could
potentially act as a independent calculation system to verify the calculations of treatment …

Treatment verification using Varian's dynalog files in the Monte Carlo system PRIMO

M Rodriguez, L Brualla - Radiation Oncology, 2019 - Springer
Background The PRIMO system is a computer software that allows the Monte Carlo
simulation of linear accelerators and the estimation of the subsequent absorbed dose …

DPM as a radiation transport engine for PRIMO

M Rodriguez, J Sempau, C Bäumer, B Timmermann… - Radiation …, 2018 - Springer
Background PRIMO is a dose verification system based on the general-purpose Monte
Carlo radiation transport code penelope, which implements an accurate physics model of …

Monte Carlo simulation of linac using PRIMO

Y Li, X Sun, Y Liang, Y Hu, C Liu - Radiation Oncology, 2022 - Springer
Abstract Background Monte Carlo simulation is considered as the most accurate method for
dose calculation in radiotherapy. PRIMO is a Monte-Carlo program with a user-friendly …

DeepBeam: a machine learning framework for tuning the primary electron beam of the PRIMO Monte Carlo software

Z Tabor, D Kabat, MPR Waligórski - Radiation Oncology, 2021 - Springer
Abstract Background Any Monte Carlo simulation of dose delivery using medical accelerator-
generated megavolt photon beams begins by simulating electrons of the primary electron …

Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

M Rodriguez, J Sempau, L Brualla - Radiation oncology, 2024 - Springer
Abstract Background Monte Carlo simulation of radiation transport for medical linear
accelerators (linacs) requires accurate knowledge of the geometrical description of the linac …

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

S Benhalouche, D Visvikis, A Le Maitre… - Medical …, 2013 - Wiley Online Library
Purpose: The objective of this study was to evaluate and validate the use of the Geant4
application for emission tomography (GATE) Monte Carlo simulation platform for clinical …

Acceptance and commissioning of a treatment planning system based on Monte Carlo calculations

J Lopez-Tarjuelo, R Garcia-Molla… - … in Cancer Research …, 2014 - journals.sagepub.com
The Monaco Treatment Planning System (TPS), based on a virtual energy fluence model of
the photon beam head components of the linac and a dose computation engine made with …

A preliminary study of in-house Monte Carlo simulations: an integrated Monte Carlo verification system

N Mukumoto, K Tsujii, S Saito, M Yasunaga… - International Journal of …, 2009 - Elsevier
PURPOSE: To develop an infrastructure for the integrated Monte Carlo verification system
(MCVS) to verify the accuracy of conventional dose calculations, which often fail to …