Adaptive pulse width control and sampling for low power pulse oximetry
Remote sensing of physiological parameters could be a cost effective approach to improving
health care, and low-power sensors are essential for remote sensing because these sensors …
health care, and low-power sensors are essential for remote sensing because these sensors …
A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms
K Li, S Warren - IEEE transactions on biomedical circuits and …, 2011 - ieeexplore.ieee.org
Pulse oximeters are central to the move toward wearable health monitoring devices and
medical electronics either hosted by, eg, smart phones or physically embedded in their …
medical electronics either hosted by, eg, smart phones or physically embedded in their …
Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications
W Karlen, JM Ansermino… - 2012 Annual International …, 2012 - ieeexplore.ieee.org
Pulse oximeters non-invasively measure heart rate and oxygen saturation and have great
potential for predicting critical illness. The photoplethysmogram (PPG) recorded from pulse …
potential for predicting critical illness. The photoplethysmogram (PPG) recorded from pulse …
Implementation and validation of a power-efficient, high-speed modulation design for wireless oxygen saturation measurement systems
P Shaltis, S Rhee, HH Asada - Proceedings of the IEEE 28th …, 2002 - ieeexplore.ieee.org
This paper describes the implementation and initial validation results of a novel power-
efficient, high-speed modulation design for wearable oxygen saturation sensor systems. The …
efficient, high-speed modulation design for wearable oxygen saturation sensor systems. The …
Onboard tagging for real-time quality assessment of photoplethysmograms acquired by a wireless reflectance pulse oximeter
K Li, S Warren, B Natarajan - IEEE Transactions on Biomedical …, 2011 - ieeexplore.ieee.org
Onboard assessment of photoplethysmogram (PPG) quality could reduce unnecessary data
transmission on battery-powered wireless pulse oximeters and improve the viability of the …
transmission on battery-powered wireless pulse oximeters and improve the viability of the …
A noise reference input to an adaptive filter algorithm for signal processing in a wearable pulse oximeter
G Comtois, Y Mendelson - 2007 IEEE 33rd Annual Northeast …, 2007 - ieeexplore.ieee.org
A wearable battery-operated pulse oximeter has been developed for rapid field triage
applications. The wearable system comprises three units: a small (Phi= 22 mm) and …
applications. The wearable system comprises three units: a small (Phi= 22 mm) and …
A low-power dynamic-range relaxed analog front end for wearable heart rate and blood oximetry sensor
H Zhang, Y Li - IEEE Sensors Journal, 2018 - ieeexplore.ieee.org
Photoplethysmogram (PPG) is widely implemented to monitor heart rate and oxygen
saturation in wearable body sensor networks for healthcare management. This paper …
saturation in wearable body sensor networks for healthcare management. This paper …
A sub-mW fully-integrated pulse oximeter front-end
KN Glaros, EM Drakakis - IEEE transactions on biomedical …, 2012 - ieeexplore.ieee.org
This paper presents the implementation of the first fully integrated pulse oximeter front-end
with a power consumption lower than 1 mW. This is enabled by system-and block-level …
with a power consumption lower than 1 mW. This is enabled by system-and block-level …
A prototype of reflection pulse oximeter designed for mobile healthcare
This paper introduces a pulse oximeter prototype designed for mobile healthcare. In this
prototype, a reflection pulse oximeter is embedded into the back cover of a smart handheld …
prototype, a reflection pulse oximeter is embedded into the back cover of a smart handheld …
Ratiometric artifact reduction in low power reflective photoplethysmography
JAC Patterson, GZ Yang - IEEE Transactions on Biomedical …, 2011 - ieeexplore.ieee.org
This paper presents effective signal-processing techniques for the compensation of motion
artifacts and ambient light offsets in a reflective photoplethysmography sensor suitable for …
artifacts and ambient light offsets in a reflective photoplethysmography sensor suitable for …