Adaptive pulse width control and sampling for low power pulse oximetry

SV Gubbi, B Amrutur - IEEE transactions on biomedical circuits …, 2014 - ieeexplore.ieee.org
Remote sensing of physiological parameters could be a cost effective approach to improving
health care, and low-power sensors are essential for remote sensing because these sensors …

A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms

K Li, S Warren - IEEE transactions on biomedical circuits and …, 2011 - ieeexplore.ieee.org
Pulse oximeters are central to the move toward wearable health monitoring devices and
medical electronics either hosted by, eg, smart phones or physically embedded in their …

Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications

W Karlen, JM Ansermino… - 2012 Annual International …, 2012 - ieeexplore.ieee.org
Pulse oximeters non-invasively measure heart rate and oxygen saturation and have great
potential for predicting critical illness. The photoplethysmogram (PPG) recorded from pulse …

Implementation and validation of a power-efficient, high-speed modulation design for wireless oxygen saturation measurement systems

P Shaltis, S Rhee, HH Asada - Proceedings of the IEEE 28th …, 2002 - ieeexplore.ieee.org
This paper describes the implementation and initial validation results of a novel power-
efficient, high-speed modulation design for wearable oxygen saturation sensor systems. The …

Onboard tagging for real-time quality assessment of photoplethysmograms acquired by a wireless reflectance pulse oximeter

K Li, S Warren, B Natarajan - IEEE Transactions on Biomedical …, 2011 - ieeexplore.ieee.org
Onboard assessment of photoplethysmogram (PPG) quality could reduce unnecessary data
transmission on battery-powered wireless pulse oximeters and improve the viability of the …

A noise reference input to an adaptive filter algorithm for signal processing in a wearable pulse oximeter

G Comtois, Y Mendelson - 2007 IEEE 33rd Annual Northeast …, 2007 - ieeexplore.ieee.org
A wearable battery-operated pulse oximeter has been developed for rapid field triage
applications. The wearable system comprises three units: a small (Phi= 22 mm) and …

A low-power dynamic-range relaxed analog front end for wearable heart rate and blood oximetry sensor

H Zhang, Y Li - IEEE Sensors Journal, 2018 - ieeexplore.ieee.org
Photoplethysmogram (PPG) is widely implemented to monitor heart rate and oxygen
saturation in wearable body sensor networks for healthcare management. This paper …

A sub-mW fully-integrated pulse oximeter front-end

KN Glaros, EM Drakakis - IEEE transactions on biomedical …, 2012 - ieeexplore.ieee.org
This paper presents the implementation of the first fully integrated pulse oximeter front-end
with a power consumption lower than 1 mW. This is enabled by system-and block-level …

A prototype of reflection pulse oximeter designed for mobile healthcare

Z Lu, X Chen, Z Dong, Z Zhao… - IEEE journal of …, 2015 - ieeexplore.ieee.org
This paper introduces a pulse oximeter prototype designed for mobile healthcare. In this
prototype, a reflection pulse oximeter is embedded into the back cover of a smart handheld …

Ratiometric artifact reduction in low power reflective photoplethysmography

JAC Patterson, GZ Yang - IEEE Transactions on Biomedical …, 2011 - ieeexplore.ieee.org
This paper presents effective signal-processing techniques for the compensation of motion
artifacts and ambient light offsets in a reflective photoplethysmography sensor suitable for …