Fast simulation of second harmonic ultrasound field using a quasi-linear method

F Prieur, TF Johansen, S Holm, H Torp - The Journal of the Acoustical …, 2012 - pubs.aip.org
Nonlinear propagation of sound has been exploited in the last 15 years in medical
ultrasound imaging through tissue harmonic imaging (THI). THI creates an image by filtering …

Fast simulation of non-linear pulsed ultrasound fields using an angular spectrum approach

Y Du, JA Jensen - Ultrasonics, 2013 - Elsevier
A fast non-linear pulsed ultrasound field simulation is presented. It is implemented based on
an angular spectrum approach (ASA), which analytically solves the non-linear wave …

A study of second harmonic generation by focused medical transducer pulses

G Wojcik, J Mould, S Ayter… - 1998 IEEE Ultrasonics …, 1998 - ieeexplore.ieee.org
Second harmonic imaging systems transmit relatively low frequency pulses, eg, 2.5 MHz,
and image the frequency-doubled second harmonic generated by acoustic nonlinearity …

[PDF][PDF] Fast 3D simulation of 2nd harmonic ultrasound field from arbitrary transducer geometries

S Dursun, T Varslot, T Johansen… - IEEE Ultrasonics …, 2005 - academia.edu
A method for fast numerical simulation of nonlinear wave propagation based on a quasi-
linear approximation has previously been presented. In the current study this method has …

Tissue harmonic imaging: A review

WR Hedrick, L Metzger - Journal of Diagnostic Medical …, 2005 - journals.sagepub.com
Nonlinear propagation creates additional high-frequency components in the ultrasound
wave (called harmonics) as the wave is transmitted through tissue. When nonlinear …

[PDF][PDF] Aberration and second harmonic imaging

T Varslot, S Masoy… - IEEE Ultrasonics …, 2005 - engineering.purdue.edu
Simulations are presented which indicate that imag-ing at the second-harmonic frequency
does not solve the problem of ultrasonic wave aberration. The nonlinearity of acoustic wave …

A new tissue harmonic imaging scheme with better fundamental frequency cancellation and higher signal-to-noise ratio

P Jiang, Z Mao, JC Lazenby - 1998 IEEE Ultrasonics …, 1998 - ieeexplore.ieee.org
Tissue Harmonic Imaging (THI) is a new ultrasound imaging technique, which uses the
harmonic components generated by nonlinear acoustic propagation through human tissues …

A new imaging technique based on the nonlinear properties of tissues

MA Averkiou, DN Roundhill… - 1997 IEEE Ultrasonics …, 1997 - ieeexplore.ieee.org
Finite amplitude sound propagating in a medium undergoes distortion due to the nonlinear
properties of the medium. The nonlinear distortion produces harmonic (and subharmonic) …

Simulation of second harmonic ultrasound fields

Y Du, H Jensen, JA Jensen - 2010 IEEE International …, 2010 - ieeexplore.ieee.org
A non-linear ultrasound imaging simulation software should be capable of simulating the
non-linear fields for any kind of transducer, focusing, apodization, and attenuation. At …

Aberration in nonlinear acoustic wave propagation

T Varslot, SE Masoy, TF Johansen… - ieee transactions on …, 2007 - ieeexplore.ieee.org
Theory and simulations are presented indicating that imaging at the second-harmonic
frequency does not solve the problem of ultrasonic wave aberration. The non-linearity of …