Verification of monitor unit calculations for non‐IMRT clinical radiotherapy: report of AAPM Task Group 114

RL Stern, R Heaton, MW Fraser… - Medical …, 2011 - Wiley Online Library
The requirement of an independent verification of the monitor units (MU) or time calculated
to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality …

Report of AAPM Task Group 219 on independent calculation‐based dose/MU verification for IMRT

TC Zhu, S Stathakis, JR Clark, W Feng… - Medical …, 2021 - Wiley Online Library
Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a
patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the …

Comparison of monitor units calculated by radiotherapy treatment planning system and an independent monitor unit verification software

P Sellakumar, C Arun, SS Sanjay, SB Ramesh - Physica Medica, 2011 - Elsevier
In radiation therapy, the monitor units (MU) needed to deliver a treatment plan are calculated
by treatment planning systems (TPS). The essential part of quality assurance is to verify the …

Patient-specific point dose measurement for IMRT monitor unit verification

L Dong, J Antolak, M Salehpour, K Forster… - International Journal of …, 2003 - Elsevier
PURPOSE: To review intensity-modulated radiation therapy (IMRT) monitor unit verification
in a phantom for 751 clinical cases. METHODS AND MATERIALS: A custom water-filled …

Clinical evaluation of monitor unit software and the application of action levels

D Georg, T Nyholm, J Olofsson… - Radiotherapy and …, 2007 - Elsevier
PURPOSE: The aim of this study was the clinical evaluation of an independent dose and
monitor unit verification (MUV) software which is based on sophisticated semi-analytical …

Quantitative analysis of patient-specific dosimetric IMRT verification

GJ Budgell, BA Perrin, JHL Mott… - Physics in Medicine & …, 2004 - iopscience.iop.org
Patient-specific dosimetric verification methods for IMRT treatments are variable, time-
consuming and frequently qualitative, preventing evidence-based reduction in the amount of …

Moving from IMRT QA measurements toward independent computer calculations using control charts

T Pawlicki, S Yoo, LE Court, SK McMillan… - Radiotherapy and …, 2008 - Elsevier
BACKGROUND AND PURPOSE: In this study, we investigated IMRT QA using Statistical
Process Control for the purpose of comparing the processes of patient-specific …

Treatment planning system calculation errors are present in most Imaging and Radiation Oncology Core-Houston phantom failures

JR Kerns, F Stingo, DS Followill, RM Howell… - International Journal of …, 2017 - Elsevier
Purpose The anthropomorphic phantom program at the Houston branch of the Imaging and
Radiation Oncology Core (IROC-Houston) is an end-to-end test that can be used to …

Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification

F Sánchez-Doblado, GH Hartmann, J Pena… - International Journal of …, 2007 - Elsevier
Purpose: Intensity-modulated radiotherapy (IMRT) represents an important method for
improving RT. The IMRT relative dosimetry checks are well established; however, open …

Dose verification for patients undergoing IMRT

JY Ting, LW Davis - Medical Dosimetry, 2001 - Elsevier
At Emory Clinic intensity-modulated radiation therapy (IMRT) was started by using dynamic
multileaf collimators (dMLC) as electronic tissue compensators in August 1998. Our IMRT …