Repeatability and reproducibility of FreeSurfer, FSL-SIENAX and SPM brain volumetric measurements and the effect of lesion filling in multiple sclerosis

C Guo, D Ferreira, K Fink, E Westman, T Granberg - European radiology, 2019 - Springer
Objectives To compare the cross-sectional robustness of commonly used volumetric
software and effects of lesion filling in multiple sclerosis (MS). Methods Nine MS patients (six …

Intra-and interscanner variability of magnetic resonance imaging based volumetry in multiple sclerosis

V Biberacher, P Schmidt, A Keshavan, CC Boucard… - Neuroimage, 2016 - Elsevier
Brain volumetric measurements in multiple sclerosis (MS) reflect not only disease-specific
processes but also other sources of variability. The latter has to be considered especially in …

Automated brain volumetrics in multiple sclerosis: a step closer to clinical application

C Wang, HN Beadnall, SN Hatton, G Bader… - Journal of Neurology …, 2016 - jnnp.bmj.com
Background Whole brain volume (WBV) estimates in patients with multiple sclerosis (MS)
correlate more robustly with clinical disability than traditional, lesion-based metrics …

Volumetric analysis from a harmonized multisite brain MRI study of a single subject with multiple sclerosis

RT Shinohara, J Oh, G Nair… - American Journal …, 2017 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: MR imaging can be used to measure structural changes in
the brains of individuals with multiple sclerosis and is essential for diagnosis, longitudinal …

Reliability of longitudinal brain volume loss measurements between 2 sites in patients with multiple sclerosis: comparison of 7 quantification techniques

F Durand-Dubief, B Belaroussi… - American journal …, 2012 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Brain volume loss is currently a MR imaging marker of
neurodegeneration in MS. Available quantification algorithms perform either direct …

Brain tissue volume changes in relapsing-remitting multiple sclerosis: correlation with lesion load

M Quarantelli, A Ciarmiello, VB Morra, G Orefice… - Neuroimage, 2003 - Elsevier
The aim of this study was to simultaneously measure in vivo volumes of gray matter (GM),
normal white matter (WM), abnormal white matter (aWM), and cerebro-spinal fluid (CSF) …

MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo …

ML Gawne-Cain, JI O'Riordan, A Coles… - Journal of Neurology …, 1998 - jnnp.bmj.com
OBJECTIVES To assess whether multiple sclerosis lesion volume measurements derived
using the fast fluid attenuated inversion recovery (fFLAIR) sequence show better …

The relationship between whole brain volume and disability in multiple sclerosis: a comparison of normalized gray vs. white matter with misclassification correction

MP Sanfilipo, RHB Benedict, J Sharma… - Neuroimage, 2005 - Elsevier
We used SPM99 to obtain normalized whole brain volumes of gray matter, white matter, and
total parenchyma in patients with multiple sclerosis (MS)(n= 41) and age-/sex-matched …

Robustness of automated methods for brain volume measurements across different MRI field strengths

R Heinen, WH Bouvy, AM Mendrik, MA Viergever… - PloS one, 2016 - journals.plos.org
Introduction Pooling of multicenter brain imaging data is a trend in studies on ageing related
brain diseases. This poses challenges to MR-based brain segmentation. The performance …

Brain MRI lesion load at 1.5 T and 3T versus clinical status in multiple sclerosis

JM Stankiewicz, BI Glanz, BC Healy… - Journal of …, 2011 - Wiley Online Library
ABSTRACT BACKGROUND/PURPOSE To assess correlation between brain lesions and
clinical status with 1.5 T and 3T magnetic resonance imaging (MRI). METHODS Brain MRI …