[引用][C] Making sense of the new ICD algorithms for the treatment of fast ventricular tachycardia

SS Barold, B Herweg - Pacing and Clinical Electrophysiology, 2009 - Wiley Online Library
The latest Medtronic implantable cardioveterdefibrillators (ICD) provide a selection of
therapies for fast ventricular tachycardia (FVT), an arrhythmia often defined by a rate …

Clinical Comparison of ICD Detection Algorithms that Include Rapid‐VT Zones

DS Hirsh, LA Chinitz, NE Bernstein… - Pacing and clinical …, 2012 - Wiley Online Library
Introduction: The safe use of antitachycardia pacing (ATP) to terminate rapid ventricular
tachycardias (VTs)(cycle length 240–320 ms) is predicated on the ability of implantable …

Antitachycardia Pacing therapy during charging: First experience with a new feature for treating fast ventricular tachycardias in Implantable Cardioverter Defibrillator …

JO Schwab, A Meijer, J Lobban, K Van Why… - Heart …, 2005 - heartrhythmjournal.com
Background: Recent studies in Implantable Cardioverter Defibrillator (ICD) patients (pts)
demonstrated the efficacy and safety of Antitachycardia Pacing (ATP) in fast ventricular …

Inappropriate implantable cardioverter-defibrillator discharge associated with a new ventricular tachycardia treatment algorithm

JE Marine, GF Tomaselli, CT Leng - Heart Rhythm, 2007 - heartrhythmjournal.com
Discussion The ability to deliver ATP for termination of monomorphic VT is an important
feature of current-generation ICDs because it allows for rapid and painless termination of …

Discriminatory therapy for very fast ventricular tachycardia in patients with implantable cardioverter defibrillators

G Sivagangabalan, S Eshoo, VE Eipper… - Pacing and clinical …, 2008 - Wiley Online Library
Objectives: We assessed the efficacy of antitachycardia pacing (ATP) and low‐energy (5J)
shock for very fast ventricular tachycardia (VFVT), cycle length 200–250 ms, in patients with …

Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging

W Schoels, D Steinhaus, WB Johnson, G O'Hara… - Heart Rhythm, 2007 - Elsevier
BACKGROUND: Previous studies in implantable cardioverter-defibrillator (ICD) patients
demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular …

An automatic algorithm based on morphological stability during fast ventricular arrhythmias predicts successful antitachycardia pacing in ICD patients: A multicenter …

R Matia, A HERNÁNDEZ‐MADRID… - Pacing and Clinical …, 2016 - Wiley Online Library
Background Different types of ventricular arrhythmias (monomorphic ventricular tachycardia
[VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac …

[PDF][PDF] 1091-211 Heart rate dynamics before the onset of ventricular tachyarrhythmias: Results of the cardioverter defibrillator registry MARITA

A Schirdewan, U Meyerfeldt, N Wessel… - Journal of the …, 2004 - academia.edu
Background: ICDs reduce mortality in primary (Prim) and secondary (Second) prevention
pts. However," overtreatment" in Prim remains a concern, potentially at the cost of spurious …

Evaluation of a programming algorithm for the third tachycardia zone in a fourth-generation implantable cardioverter-defibrillator

JJ Neglia, RB Krol, IS Giorgberidze, P Mathew… - Journal of Interventional …, 1997 - Springer
The clinical efficacy of electrical algorithms for termination of slowventricular tachycardia
(VT) and ventricular fibrillation (VF) inimplantable cardioverter-defibrillators (ICDs) is well …

Morphology of far‐field electrograms and antitachycardia pacing effectiveness among fast ventricular tachycardias occurring in ICD patients: A multicenter study

J JIMÉNEZ‐CANDIL, I Anguera… - Journal of …, 2013 - Wiley Online Library
Morphology of Far‐Field Electrograms and ATP Effectiveness Introduction Fast ventricular
tachycardias (FVT) are less likely to be terminated by antitachycardia pacing (ATP). No …