Design of a novel gamma camera with large field of view for 16N diagnosis in the primary loop of nuclear reactor
T Zhang, L Tang, Y Yan, X Bai, D Wang… - Review of Scientific …, 2024 - pubs.aip.org
The assessment of the concentration and distribution of l6 N, derived from 16 O in the
cooling water exposed to neutron irradiation, is essential for ensuring radiation safety during …
cooling water exposed to neutron irradiation, is essential for ensuring radiation safety during …
Design feasibility of gamma camera without collimator based on specific arrangement of the detectors
H Akbari-Lalimi, SA Shafiei - Nuclear Science and Techniques, 2016 - Springer
In gamma camera and single-photon emission computerized tomography, the collimator
removes most photons. Here, a gamma camera without collimator utilizes a specific …
removes most photons. Here, a gamma camera without collimator utilizes a specific …
[HTML][HTML] Low-noise reconstruction method for coded-aperture gamma camera based on multi-layer perceptron
Accurate localization of radioactive materials is crucial in homeland security and radiological
emergencies. Coded-aperture gamma camera is an interesting solution for such …
emergencies. Coded-aperture gamma camera is an interesting solution for such …
Development of compact coded aperture gamma camera for radiation monitoring in nuclear facility
DM Im, JH Jung, Y Choi, D Jang, D Kim… - 2017 IEEE Nuclear …, 2017 - ieeexplore.ieee.org
Gamma camera is a useful device to monitor various radiation sources in a wide range of
areas at nuclear facility. To localize and identify radiation sources in large area, angular …
areas at nuclear facility. To localize and identify radiation sources in large area, angular …
Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras
S Park, J Boo, M Hammig, M Jeong - Nuclear Engineering and Technology, 2021 - Elsevier
The mask parameters of a coded aperture are critical design features when optimizing the
performance of a gamma-ray camera. In this paper, experiments and Monte Carlo …
performance of a gamma-ray camera. In this paper, experiments and Monte Carlo …
[HTML][HTML] Development and evaluation of a compact gamma camera for radiation monitoring
DH Han, SJ Lee, HJ Lee, JO Kim, KH Jung… - Nuclear Engineering …, 2023 - Elsevier
The purpose of this study is to perform radiation monitoring by acquiring gamma images and
real-time optical images for 99m Tc vial source using charge couple device (CCD) cameras …
real-time optical images for 99m Tc vial source using charge couple device (CCD) cameras …
Feasibility study of a gamma camera for monitoring nuclear materials in the PRIDE facility
WJ Jo, HI Kim, SJ An, CY Lee, HK Song… - Journal of the Korean …, 2014 - Springer
Abstract The Korea Atomic Energy Research Institute (KAERI) has been developing
pyroprocessing technology, in which actinides are recovered together with plutonium. There …
pyroprocessing technology, in which actinides are recovered together with plutonium. There …
A new compact gamma camera with super resolution capability and high sensitivity for monitoring sparse radioactive sources in large area
A new compact gamma camera was developed to detect and image gamma-emitting
radioactive sources in large area. The gamma camera consists of a tungsten coded-aperture …
radioactive sources in large area. The gamma camera consists of a tungsten coded-aperture …
Compact hybrid gamma camera with a coded aperture for investigation of nuclear materials
T Lee, W Lee - Nuclear Instruments and Methods in Physics Research …, 2014 - Elsevier
Mechanical collimation commonly uses the photoelectric effect to reconstruct radiation
images. Electronic collimation (ie Compton camera) using Compton scattering has been …
images. Electronic collimation (ie Compton camera) using Compton scattering has been …
[HTML][HTML] Investigation of nuclear material using a compact modified uniformly redundant array gamma camera
T Lee, SW Kwak, W Lee - Nuclear Engineering and Technology, 2018 - Elsevier
We developed a compact gamma camera based on a modified uniformly redundant array
coded aperture to investigate the position of a UO 2 pellet emitting characteristic X-rays …
coded aperture to investigate the position of a UO 2 pellet emitting characteristic X-rays …
相关搜索
- large field primary loop
- gamma camera primary loop
- large field gamma camera
- nuclear reactor primary loop
- large field nuclear reactor
- gamma camera nuclear reactor
- aperture thickness gamma cameras
- imaging characteristics gamma cameras
- gamma camera design feasibility
- gamma camera resolution capability
- gamma camera radiation monitoring
- gamma camera high sensitivity
- gamma camera pride facility
- gamma camera development and evaluation
- gamma camera nuclear materials
- gamma camera large area