Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocity
IG Horvath, A Nemeth, Z Lenkey… - Journal of …, 2010 - journals.lww.com
Background The importance of measuring aortic pulse wave velocity (PWVao), aortic
augmentation index (Aix) and central systolic blood pressure (SBPao) has been shown …
augmentation index (Aix) and central systolic blood pressure (SBPao) has been shown …
Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements
Objectives Recently, a novel method to estimate aortic pulse wave velocity (aPWV)
noninvasively from an oscillometric single brachial cuff waveform reading has been …
noninvasively from an oscillometric single brachial cuff waveform reading has been …
Validity and reliability of aortic pulse wave velocity and augmentation index determined by the new cuff-based SphygmoCor Xcel
Aortic pulse wave velocity (AoPWV) and augmentation index (AIx) are commonly used
measures of large elastic artery stiffness and wave reflection, respectively. Recently, a new …
measures of large elastic artery stiffness and wave reflection, respectively. Recently, a new …
Non-invasive 24 hour ambulatory monitoring of aortic wave reflection and arterial stiffness by a novel oscillometric device: the first feasibility and reproducibility study
Background Surrogates of aortic wave reflection and arterial stiffness, such as augmentation
index (AIx), augmentation pressure, pulse wave velocity (PWV) and pulse pressure …
index (AIx), augmentation pressure, pulse wave velocity (PWV) and pulse pressure …
The relationship between aortic augmentation index and pulse wave velocity: an invasive study
M Sakurai, T Yamakado, H Kurachi, T Kato… - Journal of …, 2007 - journals.lww.com
Objectives The aortic augmentation index (AI) and aortic pulse wave velocity (PWV) are
known to be indicators of arterial stiffness. However, it is not clear whether aortic AI and PWV …
known to be indicators of arterial stiffness. However, it is not clear whether aortic AI and PWV …
Assessment of arterial stiffness in hypertension: comparison of oscillometric (Arteriograph), piezoelectronic (Complior) and tonometric (SphygmoCor) techniques
Background Arterial stiffness, measured as aortic pulse wave velocity (PWV), and wave
reflection, measured as augmentation index (AIx), are independent predictors for total and …
reflection, measured as augmentation index (AIx), are independent predictors for total and …
Accuracy of fully automated oscillometric central aortic blood pressure measurement techniques
M Gotzmann, M Hogeweg, FS Seibert… - Journal of …, 2020 - journals.lww.com
Background: Central aortic blood pressure (cBP) is a valuable predictor of cardiovascular
risk. The lack of fully automated measurement devices impeded an implementation in daily …
risk. The lack of fully automated measurement devices impeded an implementation in daily …
Short-term repeatability of noninvasive aortic pulse wave velocity assessment: comparison between methods and devices
A Grillo, G Parati, M Rovina, F Moretti… - American Journal of …, 2018 - academic.oup.com
BACKGROUND Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and
an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus …
an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus …
Reference values of aortic pulse wave velocity in a large healthy population aged between 3 and 18 years
EV Hidvégi, M Illyés, B Benczúr, RM Böcskei… - Journal of …, 2012 - journals.lww.com
Objective: The measurement of aortic pulse wave velocity (PWV ao) is an accepted marker
in stratifying individual cardiovascular risk in adults. There is an increasing volume of …
in stratifying individual cardiovascular risk in adults. There is an increasing volume of …
Feasibility and reproducibility of noninvasive 24-h ambulatory aortic blood pressure monitoring with a brachial cuff-based oscillometric device
Background Accumulating evidence suggests the potential superiority of office aortic blood
pressure (BP) over brachial in the management of arterial hypertension. The noninvasive …
pressure (BP) over brachial in the management of arterial hypertension. The noninvasive …
相关搜索
- oscillometric device blood pressure
- augmentation index blood pressure
- augmentation index invasive validation
- invasive validation blood pressure
- oscillometric arteriograph tonometric sphygmocor
- oscillometric device feasibility and reproducibility
- augmentation index sphygmocor xcel
- augmentation index validity and reliability
- oscillometric arteriograph arterial stiffness
- feasibility and reproducibility blood pressure