Update to practice standards for electrocardiographic monitoring in hospital settings: a scientific statement from the American Heart Association

KE Sandau, M Funk, A Auerbach, GW Barsness… - Circulation, 2017 - Am Heart Assoc
Background and Purpose: This scientific statement provides an interprofessional,
comprehensive review of evidence and recommendations for indications, duration, and …

Practice standards for electrocardiographic monitoring in hospital settings: an American Heart Association scientific statement from the Councils on Cardiovascular …

BJ Drew, RM Califf, M Funk, ES Kaufman, MW Krucoff… - Circulation, 2004 - Am Heart Assoc
The goals of electrocardiographic (ECG) monitoring in hospital settings have expanded from
simple heart rate and basic rhythm determination to the diagnosis of complex arrhythmias …

Association of implementation of practice standards for electrocardiographic monitoring with nurses' knowledge, quality of care, and patient outcomes: findings from …

M Funk, KP Fennie, KE Stephens, JL May… - … quality and outcomes, 2017 - Am Heart Assoc
Background—Although continuous electrocardiographic (ECG) monitoring is ubiquitous in
hospitals, monitoring practices are inconsistent. We evaluated implementation of American …

ACC/AHA guidelines for ambulatory electrocardiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice …

MH Crawford, SJ Bernstein, PC Deedwania… - Journal of the American …, 1999 - jacc.org
Summary...... 929 1.6. Efficacy of Antiarrhythmic Therapy...... 929 1.7. Assessment of
Pacemaker and ICD Function...... 931 1.8. Monitoring for Myocardial Ischemia...... 932 1.8. 1 …

ACC/AHA guidelines for ambulatory electrocardiography: executive summary and recommendations: a report of the American College of Cardiology/American Heart …

MH Crawford, SJ Bernstein, PC Deedwania… - Circulation, 1999 - Am Heart Assoc
Improvements in solid-state digital technology have enhanced transtelephonic transmission
of electrocardiography (ECG) data and increased the accuracy of software-based analysis …

The evolving role of ambulatory arrhythmia monitoring in general clinical practice

PJ Zimetbaum, ME Josephson - Annals of Internal Medicine, 1999 - acpjournals.org
Purpose: To evaluate the efficacy of various ambulatory electrocardiographic monitors for
the diagnosis of arrhythmia-related disorders and to provide recommendations for their use …

Heart Rhythm Society expert consensus statement on electrophysiology laboratory standards: process, protocols, equipment, personnel, and safety

DE Haines, S Beheiry, JG Akar, JL Baker, D Beinborn… - Heart rhythm, 2014 - Elsevier
The modern electrophysiology (EP) laboratory is a complex environment providing an array
of interventions for the diagnosis and treatment of heart rhythm disorders and is a result of …

Novel approach to cardiac alarm management on telemetry units

DA Whalen, PM Covelle, JC Piepenbrink… - Journal of …, 2014 - journals.lww.com
Background: General medical-surgical units struggle with how best to use cardiac monitor
alarms to alert nursing staff to important abnormal heart rates (HRs) and rhythms while …

ALARMED: adverse events in low-risk patients with chest pain receiving continuous electrocardiographic monitoring in the emergency department. A pilot study

C Atzema, MJ Schull, B Borgundvaag… - The American journal of …, 2006 - Elsevier
OBJECTIVES: Current guidelines suggest that most patients who present to an emergency
department (ED) with chest pain should be placed on a continuous electrocardiographic …

Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the …

P Kligfield, LS Gettes, JJ Bailey, R Childers, BJ Deal… - Circulation, 2007 - Am Heart Assoc
This statement examines the relation of the resting ECG to its technology. Its purpose is to
foster understanding of how the modern ECG is derived and displayed and to establish …