SHINKEI—a novel 3D isotropic MR neurography technique: technical advantages over 3DIRTSE-based imaging

JM Kasper, V Wadhwa, KM Scott, S Rozen, Y Xi… - European …, 2015 - Springer
Objectives Technical assessment of SHINKEI pulse sequence and conventional 3DIRTSE
for LS plexus MR neurography. Methods Twenty-one MR neurography examinations of the …

MR neurography with multiplanar reconstruction of 3D MRI datasets: an anatomical study and clinical applications

W Freund, A Brinkmann, F Wagner, A Dinse, AJ Aschoff… - Neuroradiology, 2007 - Springer
Introduction Extracranial MR neurography has so far mainly been used with 2D datasets. We
investigated the use of 3D datasets for peripheral neurography of the sciatic nerve. Methods …

MR neurography of brachial plexus at 3.0 T with robust fat and blood suppression

X Wang, C Harrison, YK Mariappan, K Gopalakrishnan… - Radiology, 2017 - pubs.rsna.org
Purpose To develop and evaluate magnetic resonance (MR) neurography of the brachial
plexus with robust fat and blood suppression for increased conspicuity of nerves at 3.0 T in …

3D MR neurography of the lumbosacral plexus: obtaining optimal images for selective longitudinal nerve depiction

GC Sims, E Boothe, R Joodi… - American Journal of …, 2016 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The number of centers currently performing 3D fat-
suppressed isotropic imaging is limited. If the angular orientations of the major lumbosacral …

Technical advancements in MR neurography

AJ Madhuranthakam… - Seminars in …, 2015 - thieme-connect.com
MR neurography (MRN) has evolved to become a clinically useful imaging modality for
evaluating nerve pathologies. Anatomically, nerves are often surrounded by fat and blood …

Magic angle effect: a relevant artifact in MR neurography at 3T?

T Kästel, S Heiland, P Bäumer… - American journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: MRN is an emerging diagnostic method for disorders of
peripheral nerves. However, it is unclear whether the influence of the MA on intraneural T2 …

Post-contrast 3D inversion recovery magnetic resonance neurography for evaluation of branch nerves of the brachial plexus

DB Sneag, SP Daniels, C Geannette, SC Queler… - European journal of …, 2020 - Elsevier
Abstract Purpose To compare 3.0 Tesla brachial plexus three-dimensional (3D) T2-weighted
short tau inversion recovery fast spin echo (STIR-FSE) MRI sequences before (pre-contrast …

3 Tesla MR neurography—technique, interpretation, and pitfalls

A Chhabra, PP Lee, C Bizzell, T Soldatos - Skeletal radiology, 2011 - Springer
MRI has been used for almost two decades for the evaluation of peripheral nerve disorders.
This article highlights the relative advantages and disadvantages of 3T MR neurography in …

[HTML][HTML] Diagnostic performance of deep learning–based reconstruction algorithm in 3D MR neurography

F Ensle, M Kaniewska, A Tiessen, M Lohezic… - Skeletal Radiology, 2023 - Springer
Objective The study aims to evaluate the diagnostic performance of deep learning–based
reconstruction method (DLRecon) in 3D MR neurography for assessment of the brachial and …

Brachial plexus assessment with three-dimensional isotropic resolution fast spin echo MRI: comparison with conventional MRI at 3.0 T

A Tagliafico, G Succio, CE Neumaier… - The British journal of …, 2012 - academic.oup.com
Objective: The purpose of our study was to determine whether a three-dimensional (3D)
isotropic resolution fast spin echo sequence (FSE-cube) has similar image quality and …