Far-Field 3-D Localization of Radioactive Hotspots via Four-Eyes Stereo Gamma Camera

Y Yu, S Liu, Z Zhang, Y Liu, X Liang, D Li… - … on Nuclear Science, 2022 - ieeexplore.ieee.org
In the fields of radiation environment monitoring and unknown radioactive materials search,
locating the far-field gamma-ray sources with high accurate coordinates is an important and …

[HTML][HTML] High-sensitivity stereo coded aperture gamma camera for three-dimensional localization of radioactive hotspots

Y Liu, L Shuai, D Li, S Liu, Y Wang, W Zhou, H Huang… - AIP Advances, 2022 - pubs.aip.org
This work presents a novel stereo coded aperture gamma camera based on four detection
modules placed within four quadrants. Each module includes 48× 48 strips of Bi 4 Ge 3 O 12 …

A high sensitivity 4π view gamma imager with a monolithic 3D position-sensitive detector

Q Ye, P Fan, R Wang, Z Lyu, A Hu, Q Wei, Y Xia… - Nuclear Instruments and …, 2019 - Elsevier
Imaging is an effective way to survey gamma radiation hotspots in nuclear safety, public
health and homeland security applications. The existing gamma imagers either equip a …

Design and Development of a 3D Position-Sensitive Detector for 4π View Gamma Imager Based on Dual-Ended Readout Technique

P Fan, Z Lyu, T Xu, Y Hu, Q Wei, C Zhu… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
Gamma imager capable of monitoring, detection and localization of radioactive sources is of
critical importance for nuclear safety and homeland security with the increasing use of …

Absolute gamma source positioning with position-sensitive scintillation detector arrays

R Wang, S Wang, P Fan, T Xu, Z Lyu… - 2018 IEEE Nuclear …, 2018 - ieeexplore.ieee.org
Radioactive sources are widely used in industrial and medical applications. In home-land
security, it is important to monitor radioactive source in public areas such as airport to …

Collimator-less 4π gamma imaging with 3-D position-sensitive detector

Q Ye, P Fan, Q Wei, Y Yu, S Wang… - 2016 IEEE Nuclear …, 2016 - ieeexplore.ieee.org
Fast and accurate lost radioactive source positioning is of critical importance for the
prevention of radiation damage in the accident. Traditional instruments with low detection …

Design and performance evaluation of a 4π-view gamma camera with mosaic-patterned 3D position-sensitive scintillators

Y Hu, P Fan, Z Lyu, J Huang, S Wang, Y Xia… - Nuclear Instruments and …, 2022 - Elsevier
Gamma hotspots imaging is of dramatic demand in nuclear-related industrial and homeland
security activities such as nuclear facilities monitoring, nuclear emergency response and …

Three-dimensional localization of low activity gamma-ray sources in real-time scenarios

MK Sharma, AB Alajo, HK Lee - … and Methods in Physics Research Section …, 2016 - Elsevier
Radioactive source localization plays an important role in tracking radiation threats in
homeland security tasks. Its real-time application requires computationally efficient and …

3-d volumetric gamma-ray imaging and source localization with a mobile robot

MS Lee, M Hanczor, J Chu, Z He, N Michael… - arXiv preprint arXiv …, 2018 - arxiv.org
Radiation detection has largely been a manual inspection process with point sensors such
as Geiger-Muller counters and scintillation spectrometers to date. While their observations of …

Development and Performance Evaluation of a 4π View Radiation Imaging System

Z Lyu, P Fan, T Xu, R Wang, Y Liu… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
In nuclear safety, public health and homeland security, detection of radioactive sources is
essential. The existing systems have limits in FOV and/or sensitivity. Based on gamma …