Accuracy of cuff-measured blood pressure: systematic reviews and meta-analyses

DS Picone, MG Schultz, P Otahal, S Aakhus… - Journal of the American …, 2017 - jacc.org
Background: Hypertension (HTN) is the single greatest cardiovascular risk factor worldwide.
HTN management is usually guided by brachial cuff blood pressure (BP), but questions …

Blood pressure measurement: retrospective and prospective views

H Smulyan, ME Safar - American journal of hypertension, 2011 - academic.oup.com
Measurement of the arterial blood pressure (BP) is a time-honored, vital piece of medical
information whose accuracy is seldom questioned. This review identifies the unappreciated …

Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

JE Sharman, AP Avolio, J Baulmann… - European heart …, 2017 - academic.oup.com
The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper
arm assumed the pressure obtained by this technique was a good proxy for central aortic …

Validation study to determine the accuracy of central blood pressure measurement using the Sphygmocor Xcel cuff device

MG Schultz, DS Picone, MK Armstrong, JA Black… - …, 2020 - Am Heart Assoc
Numerous devices purport to measure central (aortic) blood pressure (BP) as distinct from
conventional brachial BP. This validation study aimed to determine the accuracy of the …

Derivation and validation of diagnostic thresholds for central blood pressure measurements based on long-term cardiovascular risks

HM Cheng, SY Chuang, SH Sung, WC Yu… - Journal of the American …, 2013 - jacc.org
Objectives: This study sought to derive and validate outcome-driven thresholds of central
blood pressure (CBP) for diagnosing hypertension. Background: Current guidelines for …

Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure

G Pucci, J Cheriyan, A Hubsch, SS Hickson… - Journal of …, 2013 - journals.lww.com
Objectives: The Vicorder is a new brachial cuff-based device that estimates central blood
pressure (cBP) using a brachial-to-aortic transfer function. The aim of this study was to …

Effects of cuff size on the accuracy of blood pressure readings: the Cuff (SZ) randomized crossover trial

J Ishigami, J Charleston, ER Miller… - JAMA internal …, 2023 - jamanetwork.com
Importance Clinical practice guidelines recommend selecting an appropriately sized cuff
based on mid-arm circumference prior to measuring blood pressure (BP). To our knowledge …

Estimation of central aortic blood pressure: a systematic meta-analysis of available techniques

O Narayan, J Casan, M Szarski, AM Dart… - Journal of …, 2014 - journals.lww.com
Background: Central aortic blood pressure (cBP) is often promoted to be a superior predictor
of cardiovascular risk compared to brachial blood pressure, and brachial–central pulse …

Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and …

GS Stergiou, R Mukkamala, A Avolio… - Journal of …, 2022 - journals.lww.com
Background: Many cuffless blood pressure (BP) measuring devices are currently on the
market claiming that they provide accurate BP measurements. These technologies have …

Bi-modal arterial compliance probe for calibration-free cuffless blood pressure estimation

PM Nabeel, J Jayaraj, K Srinivasa… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Objective: We propose a calibration-free method and system for cuffless blood pressure (BP)
measurement from superficial arteries. A prototype device with bi-modal probe arrangement …