Quantification of regional fractional ventilation in human subjects by measurement of hyperpolarized 3He washout with 2D and 3D MRI
FC Horn, MH Deppe, H Marshall… - Journal of applied …, 2014 - journals.physiology.org
Multiple-breath washout hyperpolarized 3He MRI was used to calculate regional parametric
images of fractional ventilation (r) as the ratio of fresh gas entering a volume unit to the total …
images of fractional ventilation (r) as the ratio of fresh gas entering a volume unit to the total …
Improved technique for measurement of regional fractional ventilation by hyperpolarized 3He MRI
K Emami, SJ Kadlecek, JM Woodburn… - … in Medicine: An …, 2010 - Wiley Online Library
Quantitative measurement of regional lung ventilation is of great significance in assessment
of lung function in many obstructive and restrictive pulmonary diseases. A new technique for …
of lung function in many obstructive and restrictive pulmonary diseases. A new technique for …
Regional Fractional Ventilation by Using Multibreath Wash-in 3He MR Imaging
H Hamedani, JT Clapp, SJ Kadlecek, K Emami, M Ishii… - Radiology, 2016 - pubs.rsna.org
Purpose To assess the feasibility and optimize the accuracy of the multibreath wash-in
hyperpolarized helium 3 (3He) approach to ventilation measurement by using magnetic …
hyperpolarized helium 3 (3He) approach to ventilation measurement by using magnetic …
Assessment of the influence of lung inflation state on the quantitative parameters derived from hyperpolarized gas lung ventilation MRI in healthy volunteers
In this study, the effect of lung volume on quantitative measures of lung ventilation was
investigated using MRI with hyperpolarized 3He and 129Xe. Six volunteers were imaged …
investigated using MRI with hyperpolarized 3He and 129Xe. Six volunteers were imaged …
Regional ventilation mapping of the rat lung using hyperpolarized 129Xe magnetic resonance imaging
MJ Couch, A Ouriadov… - Magnetic Resonance in …, 2012 - Wiley Online Library
Lung ventilation was mapped in seven healthy male Sprague‐Dawley rats (433±24 g) using
hyperpolarized 129Xe magnetic resonance imaging (MRI) at 3.0 T, and validated with …
hyperpolarized 129Xe magnetic resonance imaging (MRI) at 3.0 T, and validated with …
A small animal model of regional alveolar ventilation using HP 3He MRI1
ZZ Spector, K Emami, MC Fischer, J Zhu, M Ishii, J Yu… - Academic radiology, 2004 - Elsevier
RATIONALE AND OBJECTIVES: The aim of this study was to establish a standardized
procedure for the measurement of regional fractional ventilation in a healthy rat model as a …
procedure for the measurement of regional fractional ventilation in a healthy rat model as a …
Imaging of lung ventilation and respiratory dynamics in a single ventilation cycle using hyperpolarized He‐3 MRI
Purpose To image respiratory dynamics and three‐dimensional (3D) ventilation during
inhalation, breath‐hold, and exhalation for evaluation of obstructive lung disease using a …
inhalation, breath‐hold, and exhalation for evaluation of obstructive lung disease using a …
Lung ventilation volumetry with same‐breath acquisition of hyperpolarized gas and proton MRI
The purpose of this work was to assess the reproducibility of percentage of ventilated lung
volume (PV) measured from hyperpolarized (HP) 3He and 1H anatomical images acquired …
volume (PV) measured from hyperpolarized (HP) 3He and 1H anatomical images acquired …
Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized 3He with Flip angle variation for offset of RF and relaxation (FAVOR)
A novel imaging method is presented, Flip Angle Variation for Offset of RF and Relaxation
(FAVOR), for rapid and efficient measurement of rat lung ventilation using hyperpolarized …
(FAVOR), for rapid and efficient measurement of rat lung ventilation using hyperpolarized …
Retrospective cine 3He ventilation imaging under spontaneous breathing conditions: a non‐invasive protocol for small‐animal lung function imaging
V Stupar, E Canet‐Soulas, S Gaillard… - NMR in Biomedicine …, 2007 - Wiley Online Library
A non‐invasive and free‐breathing hyperpolarized (HP) 3He imaging protocol for small
animals was implemented and validated on rats for lung function imaging. Animals were …
animals was implemented and validated on rats for lung function imaging. Animals were …