Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes

GB Wanna, JH Noble, ML Carlson… - The …, 2014 - Wiley Online Library
Objectives/Hypothesis Three surgical approaches: cochleostomy (C), round window (RW),
and extended round window (ERW); and two electrodes types: lateral wall (LW) and …

Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation

BP O'Connell, A Cakir, JB Hunter, DO Francis… - Otology & …, 2016 - journals.lww.com
Objectives: 1) Investigate the impact of electrode type and surgical approach on scalar
electrode location; and 2) examine the relation between electrode location and …

The importance of electrode location in cochlear implantation

BP O'Connell, JB Hunter… - Laryngoscope …, 2016 - Wiley Online Library
Objectives As indications for cochlear implantation have expanded to include patients with
more residual hearing, increasing emphasis has been placed on minimally traumatic …

Further evidence of the relationship between cochlear implant electrode positioning and hearing outcomes

S Chakravorti, JH Noble, RH Gifford… - Otology & …, 2019 - journals.lww.com
Background: Postoperative imaging studies by numerous groups have revealed that final
cochlear implant (CI) electrode position impacts audiological outcomes with scalar location …

Electrode location and audiologic performance after cochlear implantation: a comparative study between nucleus CI422 and CI512 electrode arrays

BP O'Connell, JB Hunter, RH Gifford, A Rivas… - Otology & …, 2016 - journals.lww.com
Objectives: 1) Compare rates of scala tympani (ST) insertion between Nucleus CI422 Slim
Straight electrodes and Nucleus CI512 Contour Advance electrodes; 2) examine …

Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges

ME Timm, O Majdani, T Weller, M Windeler, T Lenarz… - PLoS …, 2018 - journals.plos.org
Objectives The aim of this study was to identify anatomical indication ranges for different
lateral wall cochlear implant electrodes to support surgeons in the preoperative preparation …

Potential insertion complications with cochlear implant electrodes

A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
Objectives: The aim of this discussion paper and literature review was to estimate the
incidence of a variety of complications associated with the surgical placement of cochlear …

Impact of intrascalar electrode location, electrode type, and angular insertion depth on residual hearing in cochlear implant patients: preliminary results

GB Wanna, JH Noble, RH Gifford… - Otology & …, 2015 - journals.lww.com
Impact of Intrascalar Electrode Location, Electrode Type, an... : Otology & Neurotology Impact
of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual …

Predictive factors for short‐and long‐term hearing preservation in cochlear implantation with conventional‐length electrodes

GB Wanna, BP O'Connell, DO Francis… - The …, 2018 - Wiley Online Library
Objectives/Hypothesis The aims of this study were to investigate short‐and long‐term rates
of hearing preservation after cochlear implantation and identify factors that impact hearing …

Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes

BP O'Connell, JB Hunter, DS Haynes… - The …, 2017 - Wiley Online Library
Objectives 1) Examine angular insertion depths (AID) and scalar location of Med‐El (GmbH
Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and …