[图书][B] Small-Scale absorbed dose modelling in selective internal radiation therapy

J Högberg - 2015 - gupea.ub.gu.se
Radioembolisation (RE), with yttrium-90 (90Y) labelled microspheres, is an increasingly
common treatment method for unresectable liver tumours. The tolerable mean absorbed …

Heterogeneity of microsphere distribution in resected liver and tumour tissue following selective intrahepatic radiotherapy

J Högberg, M Rizell, R Hultborn, J Svensson… - EJNMMI research, 2014 - Springer
Background Selective arterial radioembolisation of liver tumours has increased, because of
encouraging efficacy reports; however, therapeutic parameters used in external beam …

A hepatic dose-toxicity model opening the way toward individualized radioembolization planning

S Walrand, M Hesse, F Jamar… - Journal of Nuclear …, 2014 - Soc Nuclear Med
The 50% normal-tissue complication probability (NTCP) after lobar irradiation of the liver
results in highly variable biologic effective doses depending on the modality used: a biologic …

Increased absorbed liver dose in Selective Internal Radiation Therapy (SIRT) correlates with increased sphere-cluster frequency and absorbed dose inhomogeneity

J Högberg, M Rizell, R Hultborn, J Svensson… - EJNMMI physics, 2015 - Springer
Background The higher tolerated mean absorbed dose for selective internal radiation
therapy (SIRT) with intra-arterially infused 90 Y microspheres compared to external beam …

Hepatic structural dosimetry in 90Y microsphere treatment: a Monte Carlo modeling approach based on lobular microanatomy

SA Gulec, ML Sztejnberg, JA Siegel… - Journal of Nuclear …, 2010 - Soc Nuclear Med
Selective internal radiation treatment (SIRT) via intrahepatic arterial administration of 90Y
microspheres is an effective therapeutic modality. The conventional and generally applied …

Concepts and methods for the dosimetry of radioembolisation of the liver with Y-90-loaded microspheres

A Dieudonné, M Sanchez-Garcia… - Frontiers in Nuclear …, 2022 - frontiersin.org
This article aims at presenting in a didactic way, dosimetry concepts and methods that are
relevant for radio-embolization of the liver with 90Y-microspheres. The application of the …

Radioembolization of hepatic lesions from a radiobiology and dosimetric perspective

M Cremonesi, C Chiesa, L Strigari, M Ferrari… - Frontiers in …, 2014 - frontiersin.org
Radioembolization (RE) of liver cancer with 90Y-microspheres has been applied in the last
two decades with notable responses and acceptable toxicity. Two types of microspheres are …

A proof-of-concept study of the in-vivo validation of a computational fluid dynamics model of personalized radioembolization

R Antón, J Antoñana, J Aramburu, A Ezponda… - Scientific Reports, 2021 - nature.com
Abstract Radioembolization (RE) with yttrium-90 (90Y) microspheres, a transcatheter
intraarterial therapy for patients with liver cancer, can be modeled computationally. The …

Optimization of activity and absorbed doses calculation to target/tumor and normal liver volumes in patients submitted to yttrium-90 radioembolization with glass …

P Ferreira, R Parafita, A Canudo, C Oliveira, L Rosa… - Physica Medica, 2016 - Elsevier
Introduction The model provided by manufacturers of the Y-90 microspheres does not
consider dose restrictions to tumor and to normal liver volumes, but simply calculates activity …

Dosimetry and prescription in liver radioembolization with 90Y microspheres: 3D calculation of tumor-to-liver ratio from global 99mTc-MAA SPECT information

F Mañeru, D Abós, L Bragado… - Physics in Medicine …, 2017 - iopscience.iop.org
Dosimetry in liver radioembolization with 90 Y microspheres is a fundamental tool, both for
the optimization of each treatment and for improving knowledge of the treatment effects in …