Study of the cyclic loss rate of 220Rn progeny in a 220Rn chamber by an airflow model

H Huang, G Li, Q Zhou, W Sun, T Wu, S Hu - Journal of Radioanalytical …, 2023 - Springer
To accurately measure and evaluate the radiation dose of 220Rn and its progeny, a 220Rn
chamber with an airflow model has been developed and studied, but it is difficult to take into …

Regulation and control methods for the unattached fraction of 220Rn progeny in a 220Rn progeny chamber

J Lin, D Xiao, Z He, S Li, Y Zhang, Z Wang… - Journal of Environmental …, 2021 - Elsevier
The unattached fraction of 220 Rn progeny is one of the key parameters in lung dose
evaluation models. To study the behavior of unattached 220 Rn progeny and to prepare for …

Analysis and optimization of performance parameters of the 220Rn chamber in flow-field mode using computational fluid dynamics method

SH Hu, YJ Ye, ZZ He, DT Xiao, XY Xu, JK Wang… - Nuclear Science and …, 2024 - Springer
The impact of the radiation dose produced by 222 Rn/220 Rn and its progeny on human
health has garnered increasing interest in the nuclear research field. The establishment of …

Integrating measurement of 220Rn progeny in the environment

Y Chen, J Cheng, Q Guo, J Sun, W Zhuo - Radiation Protection …, 2002 - inis.iaea.org
[en] For the purpose of evaluating the exposure due to inhalation of 220 Rn and its progeny,
a new method of integrating monitor of 222 Rn/220 Rn progeny was developed and …

Thoron experimental room at the national institute of radiological sciences (NIRS), Japan

N Kavasi, M Janik, G Prasad, Y Omori… - Radiation protection …, 2012 - academic.oup.com
A new thoron (220Rn) experimental room (TER) was established at National Institute of
Radiological Sciences in 2011 to respond to the appearance of new passive devices for …

Study on the effect of Fresh Air Ventilation system for reducing indoor 222Rn

Y Song, D Lian, H Cui, C Hou, Y Wu - Radiation Medicine and …, 2024 - mednexus.org
Objective: To explore the reduction effect for the indoor 222Rn (Rn) by Fresh Air Ventilation
(FAV) system, a novel commercial ventilation device in China. Methods: The indoor …

Study on the deposition velocity of 222Rn/220Rn progeny at varying environmental conditions

R Prajith, RP Rout, R Mishra, S Jalaluddin… - … of Radioanalytical and …, 2022 - Springer
Deposition of the 222Rn (radon) and 220Rn (thoron) progeny on surfaces is one of the
important processes that reduces the progeny activity concentration and hence inhalation …

Measuring the activity of inhaled 222Rn using a lung counting system

C Zhiwei, J Mingyan, S Maoquan - Radiation Protection …, 2015 - academic.oup.com
A new method of directly measuring 222Rn progeny in a worker′ s lung using a lung
counting system is introduced. To determine the efficiency of the lung counting system, a …

Study on continuous measurement method of {sup 220} Rn progeny concentration based on α spectroscopy

W Xijun, X Detao, S Jian, L Zhiqiang… - Atomic Energy Science …, 2014 - osti.gov
A new method of continuous measurement of the concentration of {sup 220} Rn progeny
without replacing membrane frequently was established based on a spectroscopy. A …

Numerical modeling of the sources and behaviors of 222Rn, 220Rn and their progenies in the indoor environment—A review

J Hu, G Yang, M Hegedűs, K Iwaoka, M Hosoda… - Journal of environmental …, 2018 - Elsevier
Abstract 222 Rn, 220 Rn and their short-lived progenies are well known radioactive indoor
pollutants, identified as the leading environmental cause of lung cancer next to smoking …