Fracture of cardiovascular stents in patients with congenital heart disease: theoretical and empirical considerations

DB McElhinney, AC Marshall… - Circulation …, 2013 - Am Heart Assoc
In general, the fracture resistance of a stent is influenced by multiple factors, including
features of the stent, its delivery and deployment, the vessel into which it is implanted, and …

Stent fractures in congenital heart disease

JP Breinholt, AW Nugent, MA Law… - Catheterization and …, 2008 - Wiley Online Library
Objective: To describe incidence, characteristics, predictive factors, and sequelae of stent
fractures in congenital heart disease. Background: Stent fracture in congenital heart disease …

[引用][C] Stent strut fracture: Seeing is believing

AJ Carter - Catheterization and Cardiovascular Interventions, 2008 - Wiley Online Library
4 SATJIT ADLAKHA, MUJEEB SHEIKH, JASON WU, MARK W. BURKET, UTPAL PANDYA,
WILLIAM COLYER, EHAB ELTAHAWY, CHRISTOPHER J. COOPER, Stent Fracture in the …

Incidence and clinical outcomes of stent fractures on the basis of 6,555 patients and 16,482 drug-eluting stents from 4 centers

J Kan, Z Ge, JJ Zhang, ZZ Liu, NL Tian, F Ye… - JACC: Cardiovascular …, 2016 - jacc.org
Objectives: The present study aimed to analyze the incidence of SF and its correlation with
clinical events after DES implantation and the outcome of re-intervention for symptomatic in …

Drug‐eluting stent fracture: Incidence, contributing factors, and clinical implications

T Canan, MS Lee - Catheterization and Cardiovascular …, 2010 - Wiley Online Library
Stent fracture has been observed in noncoronary vessels, especially in the superficial
femoral and popliteal arteries and with bare metal stents in saphenous vein grafts of …

In situ fracture of stents implanted for relief of pulmonary arterial stenosis in patients with congenitally malformed hearts

DB McElhinney, L Bergersen, AC Marshall - Cardiology in the Young, 2008 - cambridge.org
BackgroundOne of the most common uses of stents in patients with congenitally malformed
hearts is treatment of pulmonary arterial stenosis. Although there are reports of fractured …

Meta-analysis of incidence, clinical characteristics and implications of stent fracture

T Chakravarty, AJ White, M Buch, H Naik… - The American journal of …, 2010 - Elsevier
A meta-analysis of published studies was conducted to evaluate the incidence, predictors,
and clinical outcomes of stent fractures. Eight studies with 108 stent fractures in 5,321 …

Serial versus direct dilation of small diameter stents results in a more predictable and complete intentional transcatheter stent fracture: a PICES Bench Testing Study

MA Crystal, GJ Morgan, S Danon, RG Gray… - Pediatric …, 2018 - Springer
Balloon-expandable stents, implanted in infants and children with congenital heart disease
(CHD), often require redilation to match somatic growth. Small diameter stents may …

Stent fracture in the coronary and peripheral arteries

S Adlakha, M Sheikh, J Wu, MW Burket… - Journal of …, 2010 - Wiley Online Library
Inherent risks of stenting include restenosis and thrombosis. Recently, stent fractures have
been recognized as a complication that may result in thrombosis, perforation, restenosis …

Incidence and predictors of drug-eluting stent fracture in human coronary artery: a pathologic analysis

G Nakazawa, AV Finn, M Vorpahl, E Ladich… - Journal of the American …, 2009 - jacc.org
Objectives: The aim of this study was to perform pathologic assessment on stent fracture.
Background: Clinically, stent fracture has been reported in 1% to 2% of patients after drug …