[HTML][HTML] Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr
M Horsky, J Irrgeher, T Prohaska - Analytical and bioanalytical chemistry, 2016 - Springer
This paper critically reviews the state-of-the-art of isotope amount ratio measurements by
solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) …
solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) …
[HTML][HTML] The performance of single and multi-collector ICP-MS instruments for fast and reliable 34 S/32 S isotope ratio measurements
O Hanousek, M Brunner, D Pröfrock, J Irrgeher… - Analytical …, 2016 - pubs.rsc.org
The performance and validation characteristics of different single collector inductively
coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP …
coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP …
Sources of uncertainty in isotope ratio measurements by inductively coupled plasma mass spectrometry
PK Appelblad, I Rodushkin, DC Baxter - Analytical chemistry, 2001 - ACS Publications
A model is presented describing the effects of dead time and mass bias correction factor
uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision …
uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision …
[引用][C] Correction of Instrumental Mass Discrimination for Isotope Ratio Determination with Multi‐Collector Inductively Coupled Plasma Mass Spectrometry
This chapter contains sections titled: Historical Introduction Mass Bias in MC‐ICP‐MS
Systematics of Mass Bias Correction Models Logic of Conventional Correction Models …
Systematics of Mass Bias Correction Models Logic of Conventional Correction Models …
A critical review on isotopic fractionation correction methods for accurate isotope amount ratio measurements by MC-ICP-MS
Multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is a powerful
research tool for obtaining accurate and precise isotope amount ratios in a wide range of …
research tool for obtaining accurate and precise isotope amount ratios in a wide range of …
Observations of large mass-independent fractionation occurring in MC-ICPMS: implications for determination of accurate isotope amount ratios
Multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) suffers large bias
in isotope amount ratio determinations which has to be properly accounted for. The choice of …
in isotope amount ratio determinations which has to be properly accounted for. The choice of …
Optimisation of instrumental parameters for the precise measurement of isotope ratios with inductively coupled plasma mass spectrometry
BTG Ting, M Janghorbani - Journal of Analytical Atomic Spectrometry, 1988 - pubs.rsc.org
The effect of several instrumental operating parameters (IOPs) on the precise and accurate
measurement of isotope ratios was investigated. The IOPs of interest were: dwell time (DT) …
measurement of isotope ratios was investigated. The IOPs of interest were: dwell time (DT) …
Novel approach for the accurate determination of Se isotope ratio by multicollector ICP-MS
In this work, a method for the accurate and precise determination of 82Se/78Se isotope ratio
in natural samples of environmental and biological origin, using multicollector inductively …
in natural samples of environmental and biological origin, using multicollector inductively …
Polynomial mass bias functions for the internal standardization of isotope ratio measurements by multi-collector inductively coupled plasma mass spectrometry
W Doherty, DC Grégoire, N Bertrand - Spectrochimica Acta Part B: Atomic …, 2008 - Elsevier
The development and application of a calibration strategy for routine isotope ratio analysis
by multi-collector inductively coupled plasma mass spectrometry (ICP-MS) is described and …
by multi-collector inductively coupled plasma mass spectrometry (ICP-MS) is described and …
Systematic comparison of δ34S measurements by multicollector inductively coupled plasma mass spectrometry and evaluation of full uncertainty budget using two …
R Santamaria‐Fernandez… - Rapid Communications in …, 2008 - Wiley Online Library
A systematic comparison of δ34S measurements by multicollector inductively coupled
plasma mass spectrometry (MCICPMS) using two different standardisation approaches and …
plasma mass spectrometry (MCICPMS) using two different standardisation approaches and …
相关搜索
- icp ms uncertainty calculation
- icp ms isotope ratio
- evaluation strategies uncertainty calculation
- icp ms evaluation strategies
- isotope ratios instrumental parameters
- isotope ratios precise measurement
- implications for determination mc icpms
- accurate determination isotope ratio
- icp ms plenary lecture
- icp ms accurate determination