[HTML][HTML] Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr

M Horsky, J Irrgeher, T Prohaska - Analytical and bioanalytical chemistry, 2016 - Springer
This paper critically reviews the state-of-the-art of isotope amount ratio measurements by
solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) …

[HTML][HTML] The performance of single and multi-collector ICP-MS instruments for fast and reliable 34 S/32 S isotope ratio measurements

O Hanousek, M Brunner, D Pröfrock, J Irrgeher… - Analytical …, 2016 - pubs.rsc.org
The performance and validation characteristics of different single collector inductively
coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP …

Sources of uncertainty in isotope ratio measurements by inductively coupled plasma mass spectrometry

PK Appelblad, I Rodushkin, DC Baxter - Analytical chemistry, 2001 - ACS Publications
A model is presented describing the effects of dead time and mass bias correction factor
uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision …

[引用][C] Correction of Instrumental Mass Discrimination for Isotope Ratio Determination with Multi‐Collector Inductively Coupled Plasma Mass Spectrometry

J Meija, L Yang, Z Mester… - … and applications using …, 2012 - Wiley Online Library
This chapter contains sections titled: Historical Introduction Mass Bias in MC‐ICP‐MS
Systematics of Mass Bias Correction Models Logic of Conventional Correction Models …

A critical review on isotopic fractionation correction methods for accurate isotope amount ratio measurements by MC-ICP-MS

L Yang, S Tong, L Zhou, Z Hu, Z Mester… - Journal of Analytical …, 2018 - pubs.rsc.org
Multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is a powerful
research tool for obtaining accurate and precise isotope amount ratios in a wide range of …

Observations of large mass-independent fractionation occurring in MC-ICPMS: implications for determination of accurate isotope amount ratios

L Yang, Z Mester, L Zhou, S Gao, RE Sturgeon… - Analytical …, 2011 - ACS Publications
Multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) suffers large bias
in isotope amount ratio determinations which has to be properly accounted for. The choice of …

Optimisation of instrumental parameters for the precise measurement of isotope ratios with inductively coupled plasma mass spectrometry

BTG Ting, M Janghorbani - Journal of Analytical Atomic Spectrometry, 1988 - pubs.rsc.org
The effect of several instrumental operating parameters (IOPs) on the precise and accurate
measurement of isotope ratios was investigated. The IOPs of interest were: dwell time (DT) …

Novel approach for the accurate determination of Se isotope ratio by multicollector ICP-MS

J Karasiński, A Tupys, L Yang, Z Mester… - Analytical …, 2020 - ACS Publications
In this work, a method for the accurate and precise determination of 82Se/78Se isotope ratio
in natural samples of environmental and biological origin, using multicollector inductively …

Polynomial mass bias functions for the internal standardization of isotope ratio measurements by multi-collector inductively coupled plasma mass spectrometry

W Doherty, DC Grégoire, N Bertrand - Spectrochimica Acta Part B: Atomic …, 2008 - Elsevier
The development and application of a calibration strategy for routine isotope ratio analysis
by multi-collector inductively coupled plasma mass spectrometry (ICP-MS) is described and …

Systematic comparison of δ34S measurements by multicollector inductively coupled plasma mass spectrometry and evaluation of full uncertainty budget using two …

R Santamaria‐Fernandez… - Rapid Communications in …, 2008 - Wiley Online Library
A systematic comparison of δ34S measurements by multicollector inductively coupled
plasma mass spectrometry (MCICPMS) using two different standardisation approaches and …