Evaluation of data-driven rigid motion correction in clinical brain PET imaging
MG Spangler-Bickell, SA Hurley… - Journal of Nuclear …, 2022 - Soc Nuclear Med
Head motion during brain PET imaging can significantly degrade the quality of the
reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A …
reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A …
A systematic performance evaluation of head motion correction techniques for 3 commercial PET scanners using a reproducible experimental acquisition protocol
T Inomata, S Watanuki, H Odagiri, T Nambu… - Annals of Nuclear …, 2019 - Springer
Purposes Subject's motion during brain PET scan degrades spatial resolution and
quantification of PET images. To suppress these effects, rigid-body motion correction …
quantification of PET images. To suppress these effects, rigid-body motion correction …
The relevance of data driven motion correction in diagnostic PET
AL Kesner - European Journal of Nuclear Medicine and Molecular …, 2017 - Springer
Dear Sir, In the recently published EJNMMI article titled BQuantification, improvement, and
harmonization of small lesion detection with state-of-the-art PET^ by van der Vos, et al.[1] …
harmonization of small lesion detection with state-of-the-art PET^ by van der Vos, et al.[1] …
Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra
Head motion degrades image quality and causes erroneous parameter estimates in tracer
kinetic modeling in brain PET studies. Existing motion correction methods include frame …
kinetic modeling in brain PET studies. Existing motion correction methods include frame …
Data-driven motion detection and event-by-event correction for brain PET
98 Objectives: Existing brain PET motion correction (MC) methods include frame-based
image-registration (FIR) and correction using real-time hardware-based motion tracking …
image-registration (FIR) and correction using real-time hardware-based motion tracking …
MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner
C Catana, T Benner, A van der Kouwe… - Journal of Nuclear …, 2011 - Soc Nuclear Med
Head motion is difficult to avoid in long PET studies, degrading the image quality and
offsetting the benefit of using a high-resolution scanner. As a potential solution in an …
offsetting the benefit of using a high-resolution scanner. As a potential solution in an …
Motion correction options in PET/MRI
C Catana - Seminars in nuclear medicine, 2015 - Elsevier
Subject motion is unavoidable in clinical and research imaging studies. Breathing is the
most important source of motion in whole-body PET and MRI studies, affecting not only …
most important source of motion in whole-body PET and MRI studies, affecting not only …
Evaluation of motion correction methods in human brain PET imaging—A simulation study based on human motion data
Purpose: Motion correction in PET has become more important as system resolution has
improved. The purpose of this study was to evaluate the accuracy of event‐by‐event and …
improved. The purpose of this study was to evaluate the accuracy of event‐by‐event and …
Detecting and estimating head motion in brain PET acquisitions using raw time-of-flight PET data
PJ Schleyer, JT Dunn, S Reeves… - Physics in Medicine …, 2015 - iopscience.iop.org
Head motion during brain PET imaging is not uncommon and can negatively affect image
quality. Motion correction techniques typically either use hardware to prospectively measure …
quality. Motion correction techniques typically either use hardware to prospectively measure …
Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging
Purpose Data‐driven rigid motion estimation for PET brain imaging is usually performed
using data frames sampled at low temporal resolution to reduce the overall computation time …
using data frames sampled at low temporal resolution to reduce the overall computation time …