Common approach for compensation of axial motion artifacts in swept-source OCT and dispersion in Fourier-domain OCT

D Hillmann, T Bonin, C Lührs, G Franke… - Optics express, 2012 - opg.optica.org
Swept-source optical coherence tomography (SS-OCT) is sensitive to sample motion during
the wavelength sweep, which leads to image blurring and image artifacts. In line-field and …

Interleaved optical coherence tomography

HY Lee, H Sudkamp, T Marvdashti, AK Ellerbee - Optics Express, 2013 - opg.optica.org
We present a novel and cost-effective technique–interleaved optical coherence tomography
(iOCT)–to enhance the imaging speed of swept source OCT systems by acquiring data from …

Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography

E Azimi, B Liu, ME Brezinski - Journal of biomedical optics, 2010 - spiedigitallibrary.org
For high-speed swept-source optical coherence tomography (SS-OCT), the real-time
calibration process to convert the OCT signal to wave number space is highly essential. A …

Experimental confirmation of potential swept source optical coherence tomography performance limitations

K Zheng, B Liu, C Huang, ME Brezinski - Applied optics, 2008 - opg.optica.org
Optical coherence tomography (OCT) has demonstrated considerable potential for a wide
range of medical applications. Initial work was done in the time domain OCT (TD-OCT) …

Extra long imaging range swept source optical coherence tomography using re-circulation loops

A Bradu, L Neagu, A Podoleanu - Optics Express, 2010 - opg.optica.org
One of the main drawbacks of the swept source optical coherence tomography (SS-OCT) is
its limited axial range. A novel interferometer configuration is proposed, equipped in each …

Integrated-optics-based swept-source optical coherence tomography

VD Nguyen, N Weiss, W Beeker, M Hoekman… - Optics Letters, 2012 - opg.optica.org
We designed, fabricated, and characterized an integrated-optics-based swept-source optical
coherence tomography (SS-OCT) system in TriPleX technology. An external 1300 nm swept …

Off-axis full-field swept-source optical coherence tomography using holographic refocusing

D Hillmann, G Franke, L Hinkel, T Bonin… - … optical methods in …, 2013 - spiedigitallibrary.org
We demonstrate a full-field swept-source OCT using an off-axis geometry of the reference
illumination. By using holographic refocusing techniques, a uniform lateral resolution is …

Spatiotemporal optical coherence (STOC) manipulation suppresses coherent cross-talk in full-field swept-source optical coherence tomography

D Borycki, M Hamkało, M Nowakowski… - Biomedical optics …, 2019 - opg.optica.org
Full-field swept-source optical coherence tomography (FF-SS-OCT) provides high-resolution
depth-resolved images of the sample by parallel Fourier-domain interferometric detection …

Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher

S Vergnole, G Lamouche, ML Dufour - Optics letters, 2008 - opg.optica.org
We describe an artifact removal setup swept-source optical coherence tomography (OCT)
system that enables high-speed full-range imaging. We implement a piezoelectric fiber …

Sensitivity advantage of swept source and Fourier domain optical coherence tomography

MA Choma, MV Sarunic, C Yang, JA Izatt - Optics express, 2003 - opg.optica.org
We present theoretical and experimental results which demonstrate the superior sensitivity
of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) …