Common approach for compensation of axial motion artifacts in swept-source OCT and dispersion in Fourier-domain OCT
D Hillmann, T Bonin, C Lührs, G Franke… - Optics express, 2012 - opg.optica.org
Swept-source optical coherence tomography (SS-OCT) is sensitive to sample motion during
the wavelength sweep, which leads to image blurring and image artifacts. In line-field and …
the wavelength sweep, which leads to image blurring and image artifacts. In line-field and …
Interleaved optical coherence tomography
We present a novel and cost-effective technique–interleaved optical coherence tomography
(iOCT)–to enhance the imaging speed of swept source OCT systems by acquiring data from …
(iOCT)–to enhance the imaging speed of swept source OCT systems by acquiring data from …
Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography
E Azimi, B Liu, ME Brezinski - Journal of biomedical optics, 2010 - spiedigitallibrary.org
For high-speed swept-source optical coherence tomography (SS-OCT), the real-time
calibration process to convert the OCT signal to wave number space is highly essential. A …
calibration process to convert the OCT signal to wave number space is highly essential. A …
Experimental confirmation of potential swept source optical coherence tomography performance limitations
K Zheng, B Liu, C Huang, ME Brezinski - Applied optics, 2008 - opg.optica.org
Optical coherence tomography (OCT) has demonstrated considerable potential for a wide
range of medical applications. Initial work was done in the time domain OCT (TD-OCT) …
range of medical applications. Initial work was done in the time domain OCT (TD-OCT) …
Extra long imaging range swept source optical coherence tomography using re-circulation loops
A Bradu, L Neagu, A Podoleanu - Optics Express, 2010 - opg.optica.org
One of the main drawbacks of the swept source optical coherence tomography (SS-OCT) is
its limited axial range. A novel interferometer configuration is proposed, equipped in each …
its limited axial range. A novel interferometer configuration is proposed, equipped in each …
Integrated-optics-based swept-source optical coherence tomography
We designed, fabricated, and characterized an integrated-optics-based swept-source optical
coherence tomography (SS-OCT) system in TriPleX technology. An external 1300 nm swept …
coherence tomography (SS-OCT) system in TriPleX technology. An external 1300 nm swept …
Off-axis full-field swept-source optical coherence tomography using holographic refocusing
D Hillmann, G Franke, L Hinkel, T Bonin… - … optical methods in …, 2013 - spiedigitallibrary.org
We demonstrate a full-field swept-source OCT using an off-axis geometry of the reference
illumination. By using holographic refocusing techniques, a uniform lateral resolution is …
illumination. By using holographic refocusing techniques, a uniform lateral resolution is …
Spatiotemporal optical coherence (STOC) manipulation suppresses coherent cross-talk in full-field swept-source optical coherence tomography
D Borycki, M Hamkało, M Nowakowski… - Biomedical optics …, 2019 - opg.optica.org
Full-field swept-source optical coherence tomography (FF-SS-OCT) provides high-resolution
depth-resolved images of the sample by parallel Fourier-domain interferometric detection …
depth-resolved images of the sample by parallel Fourier-domain interferometric detection …
Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher
S Vergnole, G Lamouche, ML Dufour - Optics letters, 2008 - opg.optica.org
We describe an artifact removal setup swept-source optical coherence tomography (OCT)
system that enables high-speed full-range imaging. We implement a piezoelectric fiber …
system that enables high-speed full-range imaging. We implement a piezoelectric fiber …
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
We present theoretical and experimental results which demonstrate the superior sensitivity
of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) …
of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) …