[HTML][HTML] Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: a consensus statement by the Society for …
Parametric mapping techniques provide a non-invasive tool for quantifying tissue alterations
in myocardial disease in those eligible for cardiovascular magnetic resonance (CMR) …
in myocardial disease in those eligible for cardiovascular magnetic resonance (CMR) …
Myocardial T1 and ECV measurement: underlying concepts and technical considerations
AA Robinson, K Chow, M Salerno - JACC: Cardiovascular Imaging, 2019 - jacc.org
Myocardial native T1 and extracellular volume fraction (ECV) mapping have emerged as
cardiac magnetic resonance biomarkers providing unique insight into cardiac …
cardiac magnetic resonance biomarkers providing unique insight into cardiac …
T1 mapping in cardiac MRI
D Radenkovic, S Weingärtner, L Ricketts, JC Moon… - Heart failure …, 2017 - Springer
Quantitative myocardial and blood T 1 have recently achieved clinical utility in numerous
pathologies, as they provide non-invasive tissue characterization with the potential to …
pathologies, as they provide non-invasive tissue characterization with the potential to …
Investigating and reducing the effects of confounding factors for robust T1 and T2 mapping with cardiac MR fingerprinting
This study aims to improve the accuracy and consistency of T 1 and T 2 measurements
using cardiac MR Fingerprinting (cMRF) by investigating and accounting for the effects of …
using cardiac MR Fingerprinting (cMRF) by investigating and accounting for the effects of …
Development, validation, qualification, and dissemination of quantitative MR methods: overview and recommendations by the ISMRM quantitative MR study group
S Weingärtner, KL Desmond… - Magnetic …, 2022 - Wiley Online Library
On behalf of the International Society for Magnetic Resonance in Medicine (ISMRM)
Quantitative MR Study Group, this article provides an overview of considerations for the …
Quantitative MR Study Group, this article provides an overview of considerations for the …
Fast and accurate calculation of myocardial T1 and T2 values using deep learning Bloch equation simulations (DeepBLESS)
Purpose To propose and evaluate a deep learning model for rapid and accurate calculation
of myocardial T1/T2 values based on a previously proposed Bloch equation simulation with …
of myocardial T1/T2 values based on a previously proposed Bloch equation simulation with …
[HTML][HTML] Accelerated cardiac T1 mapping in four heartbeats with inline MyoMapNet: a deep learning-based T1 estimation approach
Purpose To develop and evaluate MyoMapNet, a rapid myocardial T 1 mapping approach
that uses fully connected neural networks (FCNN) to estimate T 1 values from four T 1 …
that uses fully connected neural networks (FCNN) to estimate T 1 values from four T 1 …
MR fingerprinting for water T1 and fat fraction quantification in fat infiltrated skeletal muscles
B Marty, PG Carlier - Magnetic resonance in medicine, 2020 - Wiley Online Library
Purpose To develop a fast MR fingerprinting (MRF) sequence for simultaneous estimation of
water T1 (T1H2O) and fat fraction (FF) in fat infiltrated skeletal muscles. Methods The MRF …
water T1 (T1H2O) and fat fraction (FF) in fat infiltrated skeletal muscles. Methods The MRF …
[HTML][HTML] Model-based myocardial T1 mapping with sparsity constraints using single-shot inversion-recovery radial FLASH cardiovascular magnetic resonance
Background This study develops a model-based myocardial T1 mapping technique with
sparsity constraints which employs a single-shot inversion-recovery (IR) radial fast low angle …
sparsity constraints which employs a single-shot inversion-recovery (IR) radial fast low angle …
Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath‐hold
S Weingärtner, S Moeller, S Schmitter… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To develop a saturation recovery myocardial T1 mapping method for the
simultaneous multislice acquisition of three slices. Methods Saturation pulse‐prepared heart …
simultaneous multislice acquisition of three slices. Methods Saturation pulse‐prepared heart …