Method for measuring venous oxygen saturation

D Boas, MA Franceschini, S Fantini - US Patent 6,985,763, 2006 - Google Patents
(57) ABSTRACT PCT Pub. Date: Jul. 25, 2002 (65) Prior Publication Data Amethod for
measuring venous Oxygen Saturation levels has US 2004/O122300 A1 Jun. 24, 2004 Steps …

Design and implementation of a multifrequency<? xpp qa?> near-infrared diffuse optical tomography system

G Gulsen, B Xiong, O Birgul… - Journal of Biomedical …, 2006 - spiedigitallibrary.org
The design and implementation of a multifrequency and multispectral diffuse optical
tomography system is described. Four wavelengths are utilized: 665, 785, 808, and 830 nm …

Combined diffuse optical tomography (DOT) and MRI system for cancer imaging in small animals

G Gulsen, O Birgul, MB Unlu… - … in cancer research …, 2006 - journals.sagepub.com
Recently, there has been a great amount of interest in developing multi-modality imaging
techniques for oncologic research and clinical studies with the aim of obtaining …

Monitoring cerebral oxygen saturation during cardiopulmonary bypass using near-infrared spectroscopy: the relationships with body<? xpp qa?> temperature and …

Y Teng, H Ding, Q Gong, Z Jia… - Journal of biomedical …, 2006 - spiedigitallibrary.org
During cardiopulmonary bypass (CPB) because of weak arterial pulsation, near-IR
spectroscopy (NIRS) is almost the only available method to monitor cerebral oxygenation …

[图书][B] Computational methods for light transport in optical tomography

T Tarvainen - 2006 - Citeseer
Optical tomography is a relatively new imaging modality in which images of the optical
properties of the medium are estimated based on measurements of visible or nearinfrared …

Determination of the optical properties of tissue-simulating phantoms from interstitial frequency domain measurements of relative fluence and phase difference

H Xu, MS Patterson - Optics Express, 2006 - opg.optica.org
We estimated the absorption and reduced scattering coefficients of tissue-simulating
phantoms from interstitial measurements of the phase difference and relative amplitude …

Comparison between a time-domain and a frequency-domain system for optical tomography

I Nissilä, JC Hebden, D Jennions… - … of biomedical optics, 2006 - spiedigitallibrary.org
The quality of phase and amplitude data from two medical optical tomography systems were
compared. The two systems are a 32-channel time-domain system developed at University …

Near‐infrared Spectroscopy, In Vivo Tissue Analysis by

MG Sowa, L Leonardi, A Matas… - Encyclopedia of …, 2006 - Wiley Online Library
In vivo near‐infrared (NIR) spectroscopy has the potential of becoming an important tool in a
number of areas in clinical medicine. Technological developments in photonics that have …

Diffuse optical tomographic reconstruction<? xpp qa?> using multifrequency data

M Burcin Unlu, O Birgul, R Shafiiha… - Journal of …, 2006 - spiedigitallibrary.org
We investigated the use of multifrequency diffuse optical tomography (MF-DOT) data for the
reconstruction of the optical parameters. The experiments were performed in a 63 mm …

[PDF][PDF] Neurophysiological monitoring: a tool for neurosurgery

RJ Sclabassi, JR Balzer, D Crammond… - Atlas of Neurosurgical …, 2006 - cdi.com
Figure 3–2 Example of median nerve evoked potentials (MSPs) and BAEPs being acquired
simultaneously with the second channel (ch 4) of BAEPs being digitally filtered. Channels 2 …