Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure

RG Hauser, DL Hayes - Heart Rhythm, 2009 - Elsevier
BACKGROUND: The Medtronic Sprint Fidelis defibrillator lead is prone to fracture and was
recalled in 2007 after 665 failures and five reported deaths. Approximately 150,000 patients …

Recommendations from the Heart Rhythm Society Task Force on lead performance policies and guidelines: developed in collaboration with the American College of …

WH Maisel, RG Hauser, SC Hammill… - Heart …, 2009 - heartrhythmjournal.com
The clinical benefits of pacemakers and implantable cardioverter defibrillators (ICDs) have
been well-established by numerous scientific studies. 1–23 Millions of devices have been …

Risk of failure of transvenous implantable cardioverter-defibrillator leads

CJW Borleffs, L van Erven, RJ van Bommel… - Circulation …, 2009 - Am Heart Assoc
Background—Despite the positive effect on mortality in selected patients, implantable
cardioverter-defibrillator therapy is also associated with potential malfunction of the …

Complications leading to surgical revision in implantable cardioverter defibrillator patients: comparison of patients with single-chamber, dual-chamber, and …

GZ Duray, J Schmitt, S Cicek-Hartvig, SH Hohnloser… - Europace, 2009 - academic.oup.com
Aims Implantable cardioverter defibrillator (ICD) technology has become more complex,
particularly with respect to biventricular resynchronization devices. The incidence of …

Performance of the St. Jude medical riata leads

AE Epstein, JH Baker II, SL Beau, TF Deering… - Heart Rhythm, 2009 - Elsevier
BACKGROUND: Recent attention has been focused on the performance of high-voltage
implantable cardioverter-defibrillator (ICD) leads. Lead-related adverse events can be …

Performance and survival of transvenous defibrillation leads: need for a European data registry

A Goette, F Cantu, L van Erven, P Geelen, F Halimi… - Europace, 2009 - academic.oup.com
Although the use of implantable cardioverter defibrillator (ICD) therapy has increased over
the last decades, the reporting of ICD lead performance is inadequate. So far, there is …

Management strategies when implanted cardioverter defibrillator leads fail: survey findings

W Xu, HJ Moore, PE Karasik, MR Franz… - Pacing and clinical …, 2009 - Wiley Online Library
Background: Defibrillator implanters have adopted different approaches to managing
failures of multicomponent implanted cardioverter defibrillator (ICD) leads. Although recent …

New material for implantable cardiac leads

SS Lobodzinski, M Laks - Journal of electrocardiology, 2009 - Elsevier
Cardiac function management devices, including implantable pacemakers and implantable
defibrillators, include at least 1 cardiac lead having an electrode for making contact with a …

Actualización en arritmias y electrofisiología cardiaca

ÁA Maíz, MA Castel, ML Gil, JLM Llorens - Revista Española de Cardiología, 2009 - Elsevier
En el presente artículo se revisan las novedades más relevantes relacionadas con la
arritmología clínica y la electrofisiología cardiaca intervencionista que han sido publicadas …

Lead malfunctions in implantable cardioverter defibrillators: where are we and where should we go?

A Corrado, G Gasparini, A Raviele - Europace, 2009 - academic.oup.com
Implantable cardioverter defibrillators (ICDs) have become the standard of care for the
prevention of sudden cardiac death and for the management of ventricular arrhythmias. In …