Advanced insulin bolus advisor based on run-to-run control and case-based reasoning

P Herrero, P Pesl, M Reddy, N Oliver… - IEEE journal of …, 2014 - ieeexplore.ieee.org
This paper presents an advanced insulin bolus advisor for people with diabetes on multiple
daily injections or insulin pump therapy. The proposed system, which runs on a smartphone …

Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies

PG Jacobs, J El Youssef, J Castle… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
Automated control of blood glucose in patients with type-1 diabetes has not yet been fully
implemented. The aim of this study was to design and clinically evaluate a system that …

Reducing Risks in Type 1 Diabetes Using Control

P Colmegna, RSS Pena, R Gondhalekar… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
A control scheme was designed in order to reduce the risks of hyperglycemia and
hypoglycemia in type 1 diabetes mellitus (T1DM). This structure is composed of three main …

Feasibility study of a bio-inspired artificial pancreas in adults with type 1 diabetes

M Reddy, P Herrero, M El Sharkawy, P Pesl… - Diabetes technology …, 2014 - liebertpub.com
Background: This study assesses proof of concept and safety of a novel bio-inspired artificial
pancreas (BiAP) system in adults with type 1 diabetes during fasting, overnight, and …

Bio-Inspired Glucose Control in Diabetes Based on an Analogue Implementation of a -Cell Model

I Pagkalos, P Herrero, C Toumazou… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
This paper presents a bio-inspired method for in-vivo control of blood glucose based on a
model of the pancreatic β-cell. The proposed model is shown to be implementable using low …

Linear parameter-varying control to minimize risks in type 1 diabetes

P Colmegna, RSS Pena - IFAC Proceedings Volumes, 2014 - Elsevier
This work provides a time-varying controller to improve the glycemic regulation in Type 1
Diabetes Mellitus (T1DM) patients. To this end, a Linear Parameter-Varying (LPV) control is …

Live demonstration: A handheld bio-inspired artificial pancreas for treatment of diabetes

P Herrero, M El Sharkawy, P Pesl… - … Circuits and Systems …, 2014 - ieeexplore.ieee.org
Good control of glucose in diabetes requires minimisation of high and low blood glucose
excursions and is critical to reducing the incidence of complications and improving quality of …

胰岛素泵

卡尔文, 西姆 - 2014 - Google Patents
CN104054081A - 胰岛素泵- Google Patents CN104054081A - 胰岛素泵- Google Patents
胰岛素泵 Download PDF Info Publication number CN104054081A CN104054081A …

Biosensor Design with Molecular Engineering and Nanotechnology

TT Le, CJ Johnson, J Trzebinski, AEG Cass - Body Sensor Networks, 2014 - Springer
The concept of a biosensor is well established and the idea of integrating a molecular
recognition layer with a base sensor, such as analyte binding or reaction at the former …