Transvenous implantable cardioverter‐defibrillator (ICD) lead performance: a meta‐analysis of observational studies

R Providência, DB Kramer, D Pimenta… - Journal of the …, 2015 - Am Heart Assoc
Background Despite the widespread use of implantable cardioverter‐defibrillators (ICD s) in
clinical practice, concerns exist regarding ICD lead durability. The performance of specific …

Sudden death in patients with cardiac implantable electronic devices

ZH Tseng, RM Hayward, NM Clark… - JAMA internal …, 2015 - jamanetwork.com
Importance Interrogations and autopsies of sudden deaths with cardiac implantable
electronic devices (CIEDs) are rarely performed. Therefore, causes of sudden deaths with …

[HTML][HTML] The entirely subcutaneous defibrillator–a new generation and future expectations

H Ali, P Lupo, R Cappato - Arrhythmia & electrophysiology review, 2015 - ncbi.nlm.nih.gov
Although conventional implantable cardioverter-defibrillators (ICDs) have proved effective in
the prevention of sudden cardiac death (SCD), they still appear to be limited by non-trivial …

The mismatch between patient life expectancy and the service life of implantable devices in current cardioverter-defibrillator therapy: a call for larger device batteries

J Neuzner - Clinical Research in Cardiology, 2015 - Springer
Abstract In 2005, Bob Hauser published a paper in the Journal of the American College of
Cardiology entitled “The growing mismatch between patient longevity and the service life of …

Transvenous Implantable Cardioverter‐Defibrillator Lead Reliability: Implications for Postmarket Surveillance

DB Kramer, LA Hatfield, D McGriff, CR Ellis… - Journal of the …, 2015 - Am Heart Assoc
Background As implantable cardioverter‐defibrillator technology evolves, clinicians and
patients need reliable performance data on current transvenous implantable cardioverter …

[图书][B] Interventional cardiac electrophysiology: a multidisciplinary approach

S Saksena - 2015 - books.google.com
Interventional Cardiac Electrophysiology is the first and only comprehensive, state-of-the-art
textbook written for practitioners in multiple specialties involved in the care of the arrhythmia …

[HTML][HTML] Heart failure with reduced ejection fraction and a narrow QRS complex: combination of a subcutaneous defibrillator with cardiac contractility modulation

S Röger, M Borggrefe, J Kuschyk - Journal of Atrial Fibrillation, 2015 - ncbi.nlm.nih.gov
Cardiac contractility modulation (CCM) is a relatively new electrical therapy for heart failure
patients with reduced ejection fraction. The majority of patients eligible for CCM will also …

Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis

SD Pokorney, K Zhou, DB Matchar… - Journal of …, 2015 - Wiley Online Library
Riata Decision Analysis Introduction Riata and Riata ST implantable cardioverter‐
defibrillator (ICD) leads (St. Jude Medical, Sylmar, CA, USA) can develop conductor cable …

The subcutaneous cardioverter-defibrillator: When less is more

J Kuschyk, B Rudic, I Akin, M Borggrefe… - …, 2015 - Springer
Zusammenfassung Einleitung In den letzten Dekaden hat die konsequente
Weiterentwicklung von implantierbaren Kardioverter-Defibrillatoren (ICD) die Behandlung …

Managing patients with advisory defibrillator leads: what can we learn from published data?

FA Bracke, BM van Gelder - Netherlands Heart Journal, 2015 - Springer
Defibrillator lead advisories stir a lot of emotions, both with patients and physicians, and this
may influence lead management. We reviewed the literature for a more evidence-based …