Sex differences in outcomes of primary prevention implantable cardioverter-defibrillator therapy: combined registry data from eleven European countries

C Sticherling, B Arendacka, JH Svendsen… - Ep …, 2018 - academic.oup.com
Aims Therapy with an implantable cardioverter defibrillator (ICD) is established for the
prevention of sudden cardiac death (SCD) in high risk patients. We aimed to determine the …

[HTML][HTML] Feasibility of extravascular pacing with a novel substernal electrode configuration: the Substernal Pacing Acute Clinical Evaluation study

DP Sholevar, S Tung, V Kuriachan, P Leong-Sit… - Heart Rhythm, 2018 - Elsevier
Background Subcutaneous implantable cardioverter-defibrillators provide an alternative to
transvenous defibrillation but require higher shock outputs and offer no antitachycardia …

Utility of risk scores to predict adverse events in cardiac lead extraction

L Segreti, M Giannotti Santoro, A Di Cori… - Expert Review of …, 2018 - Taylor & Francis
Introduction: Increasing device implantations, patient comorbidities, and longer life
expectancy contribute to an increased need for lead extraction. Even if transvenous lead …

Reimplantation after lead removal

MB Elshazly, KG Tarakji - Cardiac Electrophysiology …, 2018 - cardiacep.theclinics.com
Over the last 6 decades, cardiovascular implantable electronic devices (CIEDs), including
permanent pacemakers, implantable cardioverterdefibrillators (ICDs), and cardiac …

Lead extraction in a non-infectious situation–it's becoming a major cause gradually

K Imai - Journal of Cardiology, 2018 - journal-of-cardiology.com
In the past decade, lead extraction procedure in the management of the leads of cardiac
implantable electrical devices (CIEDs) has increased year by year. The major indication for …

Frequency of need for antitachycardia or antibradycardia pacing or cardiac resynchronization therapy in patients with a single-chamber implantable cardioverter …

MC Melles, SC Yap, RE Bhagwandien, R Sakhi… - The American Journal of …, 2018 - Elsevier
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is unable to deliver
antitachycardia pacing (ATP), bradycardia pacing, and cardiac resynchronization therapy …

Long‐term reliability of the defibrillator lead inserted by the extrathoracic subclavian puncture

M Watanabe, H Yokoshiki, H Mitsuyama… - Journal of …, 2018 - Wiley Online Library
Background As the transvenous defibrillator lead is fragile and its failure may cause a life‐
threatening event, reliable insertion techniques are required. While the extrathoracic …

[HTML][HTML] Interaction between shock coils increased the incidence of inappropriate therapies and lead failure in implantable cardioverter defibrillator

M El Garhy, MA Ohlow, B Lauer - Indian Pacing and Electrophysiology …, 2018 - Elsevier
Aims Shock coil interaction in patients with multiple implantable cardioverter defibrillator
(ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil …

Iatrogenic Aspects of Cardiac Device Therapy

S Röger, J Kuschyk - Iatrogenicity: Causes and Consequences of …, 2018 - books.google.com
The approach to cardiac pacemaker implantation has evolved over the past half century.
The early trend from the epicardial approach to the simpler transvenous cutdown led to the …