[HTML][HTML] Catheter ablation of atrial fibrillation: state of the art and future perspectives

L Rottner, B Bellmann, T Lin, B Reissmann… - Cardiology and …, 2020 - Springer
Abstract Purpose of Review Atrial fibrillation (AF), the most common sustained arrhythmia, is
associated with high rates of morbidity and mortality. Maintenance of stable sinus rhythm …

Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial

M Duytschaever, J Vijgen, T De Potter, D Scherr… - EP …, 2020 - academic.oup.com
Aims To evaluate the safety and effectiveness of pulmonary vein isolation in paroxysmal
atrial fibrillation (PAF) using a standardized workflow aiming to enclose the veins with …

Natriuretic peptides: biomarkers for atrial fibrillation management

A Sepehri Shamloo, A Bollmann, N Dagres… - Clinical Research in …, 2020 - Springer
In clinical practice, atrial fibrillation (AF) is known as the most common sustained arrhythmia.
Therefore, identification of individuals at risk of AF development/recurrence or its associated …

Characteristics of esophageal injury in ablation of atrial fibrillation using a high-power short-duration setting

T Kaneshiro, M Kamioka, N Hijioka… - Circulation …, 2020 - Am Heart Assoc
Background: The mechanism of esophageal thermal injury (ETI; esophageal mucosal injury
and periesophageal nerve injury leading to gastric hypomotility) remains unknown when …

Efficacy of high-power and short-duration ablation in patients with atrial fibrillation: a prospective randomized controlled trial

DG Shin, J Ahn, SJ Han, HE Lim - EP Europace, 2020 - academic.oup.com
Aims The formation of radiofrequency lesions depends on the power and duration of
ablation, and the contact force (CF). Although high power (HP) creates continuous and …

Efficacy and safety of ablation index-guided catheter ablation for atrial fibrillation: an updated meta-analysis

A Ioannou, N Papageorgiou, WY Lim… - EP …, 2020 - academic.oup.com
Aims Despite recent advances in catheter ablation for atrial fibrillation (AF), pulmonary vein
reconnection (PVR), and AF recurrence remain significantly high. Ablation index (AI) is a …

Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study

S Castrejón-Castrejón, M Martínez Cossiani… - Journal of Interventional …, 2020 - Springer
Purpose Pulmonary vein (PV) isolation (PVI) by point-by-point radiofrequency application
(PPRF) results in longer procedures than that achieved by single-shot ablation techniques …

Esophageal endoscopy after catheter ablation of atrial fibrillation using ablation-index guided high-power: Frankfurt AI-HP ESO-I

S Chen, KRJ Chun, S Bordignon, L Urbanek… - Clinical …, 2020 - jacc.org
Objectives This study sought to investigate the safety profile of a novel ablation index–
guided high-power short-duration (AI-HP) pulmonary vein isolation (PVI) in terms of …

[HTML][HTML] Impact of local left atrial wall thickness on the incidence of acute pulmonary vein reconnection after Ablation Index-guided atrial fibrillation ablation

MJ Mulder, MJB Kemme, AMD Hagen… - IJC Heart & …, 2020 - Elsevier
Abstract Background Although Ablation Index (AI)-guided ablation facilitates creation of
lesions of consistent depth, pulmonary vein (PV) reconnection is still commonly observed …

Pulmonary vein isolation using ablation index vs. CLOSE protocol with a surround flow ablation catheter

B Berte, G Hilfiker, F Moccetti, T Schefer… - EP …, 2020 - academic.oup.com
Aims Pulmonary vein isolation (PVI) using ablation index (AI) incorporates stability, contact
force (CF), time, and power. The CLOSE protocol combines AI and≤ 6 mm interlesion …