The impact of auditory spectral resolution on listening effort revealed by pupil dilation

MB Winn, JR Edwards, RY Litovsky - Ear and hearing, 2015 - journals.lww.com
Objectives: This study measured the impact of auditory spectral resolution on listening effort.
Systematic degradation in spectral resolution was hypothesized to elicit corresponding …

Use of research interfaces for psychophysical studies with cochlear-implant users

RY Litovsky, MJ Goupell, A Kan… - Trends in …, 2017 - journals.sagepub.com
A growing number of laboratories are using research interfaces to conduct experiments with
cochlear-implant (CI) users. Because these interfaces bypass a subject's clinical sound …

Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration

JA Bierer - The Journal of the Acoustical Society of America, 2007 - pubs.aip.org
The efficacy of cochlear implants is limited by spatial and temporal interactions among
channels. This study explores the spatially restricted tripolar electrode configuration and …

Auditory cortical images of cochlear-implant stimuli: dependence on electrode configuration

JA Bierer, JC Middlebrooks - Journal of neurophysiology, 2002 - journals.physiology.org
This study examines patterns of auditory cortical activity elicited by single-pulse cochlear
implant stimuli that vary in electrode configuration, cochlear place of stimulation, and …

The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants

JHM Frijns, JJ Briaire, JJ Grote - Otology & neurotology, 2001 - journals.lww.com
Background Multichannel cochlear implants give better speech understanding than single-
channel devices. They are intended to make use of the tonotopic organization of the cochlea …

Auditory implant research at the House Ear Institute 1989–2013

RV Shannon - Hearing research, 2015 - Elsevier
Abstract The House Ear Institute (HEI) had a long and distinguished history of auditory
implant innovation and development. Early clinical innovations include being one of the first …

Modeling the electrode–neuron interface of cochlear implants: Effects of neural survival, electrode placement, and the partial tripolar configuration

JH Goldwyn, SM Bierer, JA Bierer - Hearing research, 2010 - Elsevier
The partial tripolar electrode configuration is a relatively novel stimulation strategy that can
generate more spatially focused electric fields than the commonly used monopolar …

Simulating the effect of spread of excitation in cochlear implants

M Bingabr, B Espinoza-Varas, PC Loizou - Hearing research, 2008 - Elsevier
A model was developed to simulate acoustically the effects of excitation spread in cochlear
implants (CI). Based on neurophysiologic data, the proposed model simulates the electrical …

Psychophysics of a prototype peri-modiolar cochlear implant electrode array

LT Cohen, E Saunders, GM Clark - Hearing research, 2001 - Elsevier
Psychophysical measurements were performed in three hearing-impaired adult subjects
implanted with a CI22 cochlear prosthesis (Cochlear Ltd.) fitted with a developmental peri …

Effects of electrode design and configuration on channel interactions

GS Stickney, PC Loizou, LN Mishra, PF Assmann… - Hearing research, 2006 - Elsevier
A potential shortcoming of existing multichannel cochlear implants is electrical-field
summation during simultaneous electrode stimulation. Electrical-field interactions can …