Radiation protection for the fluoroscopy operator and staff

QC Meisinger, CM Stahl, MP Andre… - American Journal of …, 2016 - Am Roentgen Ray Soc
OBJECTIVE. The purposes of this article are to review available data regarding the range of
protection devices and garments with a focus on eye protection and to summarize …

Personal radiation protection and corresponding dosimetry in interventional radiology: an overview and future developments

AM König, R Etzel, RP Thomas… - RöFo-Fortschritte auf …, 2019 - thieme-connect.com
Hintergrund Röntgenstrahlen haben ein sehr breites Anwendungsspektrum in der Medizin.
Mit dem Trend zu minimalinvasiven Eingriffen steigen besonders die Zahlen …

Editor's Choice–European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on radiation safety

B Modarai, S Haulon, E Ainsbury, D Böckler… - European journal of …, 2023 - ejves.com
The majority of studies investigating the effectiveness of radiation shields focus on
procedures performed by cardiologists. These studies are, nevertheless, relevant also for …

Enhanced radiation shielding with conformal light-weight nanoparticle–polymer composite

Q Li, Q Wei, W Zheng, Y Zheng, N Okosi… - … applied materials & …, 2018 - ACS Publications
This article reports a new property enabled by nanoparticles, where bismuth nanoparticles
added in a polymer matrix can block X-ray radiation several times more efficient than …

Chemically bonded tungsten-based polymer composite for X-rays shielding applications

A Bijanu, R Paulose, AS Tomar, V Agrawal… - Materials Today …, 2022 - Elsevier
Lead-free metal-polymer composite based X-ray shielding apparel has been of great
concern in recent years due to its flexibility, less toxicity, lightweight, etc. The conventional …

Flexible, chemically bonded Bi-PVA–PVP composite for enhanced diagnostic X-ray shielding applications

A Bijanu, G Rajak, R Paulose, R Arya… - Journal of Inorganic and …, 2023 - Springer
The motto of this work is to develop a flexible, lightweight metal-polymer composite for
shielding diagnostic X-rays (40–140 kV) as an alternative to toxic lead/lead composite for …

Lead aprons are a lead exposure hazard

KM Burns, JM Shoag, SS Kahlon, PJ Parsons… - Journal of the American …, 2017 - Elsevier
Purpose To determine whether lead-containing shields have lead dust on the external
surface. Methods Institutional review board approval was obtained for this descriptive study …

Assessment of the Attenuation Properties of Commercial Lead-Free Radiation-Shielding Composite Materials Against Medical X-rays

A Trajkovska Petkoska - Journal of Composites Science, 2023 - mdpi.com
Six commercial, lead-free, radiation protective materials were tested for their attenuation
across a range of X-ray energies used in medical diagnostic imaging and interventional …

Radiation exposure during angiographic interventions in interventional radiology–risk and fate of advanced procedures

HL Kaatsch, J Schneider, C Brockmann… - … journal of radiation …, 2022 - Taylor & Francis
Purpose Advanced angiographic procedures in interventional radiology are becoming more
important and are more frequently used, especially in the treatment of several acute life …

Green lightweight lead-free Gd2O3/epoxy nanocomposites with outstanding X-ray attenuation performance

LBT La, C Leatherday, YK Leong, HP Watts… - … Science and Technology, 2018 - Elsevier
This work describes the design, preparation, and characterization of an environmentally
friendly, clinically safe, and lightweight Gd 2 O 3/epoxy nanocomposite (Gd nanocomposite) …