[HTML][HTML] Radio Frequency Coils for Hyperpolarized 13C Magnetic Resonance Experiments with a 3T MR Clinical Scanner: Experience from a Cardiovascular Lab
Hyperpolarized 13C magnetic resonance (MR) is a promising technique for the noninvasive
assessment of the regional cardiac metabolism since it permits heart physiology studies in …
assessment of the regional cardiac metabolism since it permits heart physiology studies in …
Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs: Comparison Between Surface and Volume Radiofrequency Coils
Cardiac metabolism assessment with hyperpolarized 13 C magnetic resonance
spectroscopy in pig models requires the design of dedicated coils capable of providing large …
spectroscopy in pig models requires the design of dedicated coils capable of providing large …
Coil Sensitivity Estimation with Perturbing Sphere Method: Application to 13C Birdcages
G Giovannetti, F Frijia, L Menichetti… - Applied Magnetic …, 2012 - Springer
Radiofrequency coils in magnetic resonance systems are used to irradiate nuclear spins
and to pick up the signals emitted by the nuclei with high signal-to-noise ratio and large …
and to pick up the signals emitted by the nuclei with high signal-to-noise ratio and large …
Transmit-Only/Receive-Only Radiofrequency System for Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs
Hyperpolarized 13 C magnetic resonance spectroscopy in pig models enables metabolic
activity mapping, providing a powerful tool for the study of the heart physiology, but requires …
activity mapping, providing a powerful tool for the study of the heart physiology, but requires …
Simulation and comparison of coils for Hyperpolarized 13C MRS cardiac metabolism studies in pigs
Abstract Hyperpolarized 13 C Magnetic Resonance represents a promising modality for in
vivo spectroscopy since it provides a unique opportunity for the non-invasive assessment of …
vivo spectroscopy since it provides a unique opportunity for the non-invasive assessment of …
Efficiency evaluation of a 13C Magnetic Resonance birdcage coil: Theory and comparison of four methods
Radiofrequency coils in Magnetic Resonance systems are used to produce a homogeneous
B1 field for exciting the nuclei and to pick up the signals emitted by the nuclei with high …
B1 field for exciting the nuclei and to pick up the signals emitted by the nuclei with high …
A fast and simple method for calibrating the flip angle in hyperpolarized 13C MRS experiments
G Giovannetti, F Frijia, A Flori… - … Resonance Part B …, 2015 - Wiley Online Library
Hyperpolarized 13C Magnetic resonance represents a promising modality for in vivo studies
of intermediary metabolism of bio‐molecules and new biomarkers. Although it represents a …
of intermediary metabolism of bio‐molecules and new biomarkers. Although it represents a …
A novel method for coil efficiency estimation: Validation with a 13C birdcage
G Giovannetti, F Frijia, V Hartwig… - … Resonance Part B …, 2012 - Wiley Online Library
Coil efficiency, defined as the B1 magnetic field induced at a given point on the square root
of supplied power P, is an important parameter that characterizes both the transmit and …
of supplied power P, is an important parameter that characterizes both the transmit and …