China's 10-year progress in DC gas-insulated equipment: From basic research to industry perspective
The construction of the future energy structure of China under the 2050 carbon-neutral
vision requires compact direct current (DC) gas-insulation equipment as important nodes …
vision requires compact direct current (DC) gas-insulation equipment as important nodes …
Insight into charge-induced flashover at the gas–solid interface in DC gas-insulated systems
The proliferation of urbanization and the integration of new energy sources have stimulated
the development of gas-insulated transmission lines and switchgear (GIL/GIS). In particular …
the development of gas-insulated transmission lines and switchgear (GIL/GIS). In particular …
Understanding Effects of Deep Traps on DC Surface Flashover Characteristics of Epoxy/MWCNTs-TiO2 Nanocomposites in a Vacuum
Z Li, K Ma, B Li, X Wang, M Li, J Liu… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Surface flashover is likely to be triggered when a high electric field is applied due to its
voltage being much lower than the breakdown voltage of either gas or solid, which restricts …
voltage being much lower than the breakdown voltage of either gas or solid, which restricts …
Optimum design of spacer material of gas-insulated switchgear by utilizing the technology of functionally graded material using different artificial optimization …
Considering the reliable operation of Gas–Insulated Switchgear (GIS) system within higher
voltages, the optimal performance of solid spacer is one of the most effective topologies in …
voltages, the optimal performance of solid spacer is one of the most effective topologies in …
The flashover of epoxy initiated by micron metal particles under DC voltage: phenomenon and mechanism
B Qi, Z Yang, X Yang, M Huang, C Gao… - Journal of Physics D …, 2022 - iopscience.iop.org
Epoxy post-insulator is one of the key parts in SF 6 gas-insulated DC wall bushing, which is
irreplaceable in high voltage direct current transmission projects. Flashovers occur on post …
irreplaceable in high voltage direct current transmission projects. Flashovers occur on post …
Parameter design of functionally graded materials for tri-post insulator in HVDC GIL under stationary and transient conditions
J Dong, B Du, H Liang, H Yao - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
This article conducts a simulation study on the parameter design of the superficially
nonlinear-conductivity material (SNCM) and the permittivity functionally graded material …
nonlinear-conductivity material (SNCM) and the permittivity functionally graded material …
Electric field intensity minimization in three-phase gas-insulated busduct with metal inserts under delamination
KV Subrahmanyam, KM Rosalina - The International Journal of Advanced …, 2023 - Springer
Irrespective of the state of the environment, the power system network must be maintained
uninterrupted. Many manufacturing and switching problems, including delamination …
uninterrupted. Many manufacturing and switching problems, including delamination …
Reliability of FGM bulb type spacer in three-phase gas insulated busduct with protrusion and depression defects under particle contamination
KV Subrahmanyam, KM Rosalina - International Journal of System …, 2024 - Springer
Electrical substations must operate reliably and effectively no matter the environment they
are located in, and they must also repair damage fast. Due to a number of problems that …
are located in, and they must also repair damage fast. Due to a number of problems that …
Multi-dimensional functionally graded insulator for HVDC compact gas insulated apparatus
J Dong, B Du, H Liang, H Yao - Journal of Physics D: Applied …, 2023 - iopscience.iop.org
Gas insulated switchgear may be exposed to AC-DC mixed voltages in bipolar high voltage
direct current (HVDC) systems. To improve the insulation performance of the epoxy …
direct current (HVDC) systems. To improve the insulation performance of the epoxy …
Fabrication of Multidimensional Functionally Graded Insulator for HVDC GIS
J Dong, H Liang, B Du, H Yao - 2023 IEEE 4th International …, 2023 - ieeexplore.ieee.org
Gas insulated switchgear (GIS) can encounter the voltage that combines both AC and DC
components in a bipolar HVDC. systems. To enhance the insulation performance of the …
components in a bipolar HVDC. systems. To enhance the insulation performance of the …