A review of solid-state circuit breakers
R Rodrigues, Y Du, A Antoniazzi… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Although conventional electromechanical circuit breakers have a proven record as effective
and reliable devices for circuit protection, emerging power distribution technologies and …
and reliable devices for circuit protection, emerging power distribution technologies and …
Review of DC circuit breaker application
Q Huo, J Xiong, N Zhang, X Guo, L Wu, T Wei - Electric Power Systems …, 2022 - Elsevier
The development of flexible AC transmission and multi-terminal DC grid is in an urgent
demand for DC circuit breaker (DCCB) technology with faster switching speed, strong …
demand for DC circuit breaker (DCCB) technology with faster switching speed, strong …
Design of solid-state circuit breaker-based protection for DC shipboard power systems
LL Qi, A Antoniazzi, L Raciti… - IEEE Journal of Emerging …, 2016 - ieeexplore.ieee.org
Fast increasing dc fault currents in dc shipboard distribution systems require fast dc
protective devices and protection methods. Solid-state circuit breakers (SSCBs) inherently …
protective devices and protection methods. Solid-state circuit breakers (SSCBs) inherently …
A review on protection of DC microgrids
The DC microgrid has become a typical distribution network due to its excellent
performance. However, a well-designed protection scheme still remains a challenge for DC …
performance. However, a well-designed protection scheme still remains a challenge for DC …
Future shipboard MVdc system protection requirements and solid-state protective device topological tradeoffs
RM Cuzner, V Singh - IEEE Journal of Emerging and Selected …, 2017 - ieeexplore.ieee.org
The search for the optimum architecture for shipboard medium voltage dc integrated power
systems must take into account the short-circuit protection in addition to overarching goals of …
systems must take into account the short-circuit protection in addition to overarching goals of …
Local measurement-based protection coordination system for a standalone DC microgrid
A reliable protection coordination system between the power electronic converters and solid-
state device-based fast protection unit in a standalone dc microgrid supplied by a wave …
state device-based fast protection unit in a standalone dc microgrid supplied by a wave …
LVDC SiC MOSFET analog electronic fuse with self-adjusting tripping time depending on overcurrent condition
D Marroqui, A Garrigós… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article deals with the design of an electronic fuse for 380 V dc distribution systems. It
has been devised for applications that require current limitation up to 3 A, so approximately …
has been devised for applications that require current limitation up to 3 A, so approximately …
SiC solid state circuit breaker with an adjustable current-time tripping profile
This paper reports a SiC-based solid-state circuit breaker (SSCB) with an adjustable current-
time (It) tripping profile for both ultrafast short circuit protection and overload protection. The …
time (It) tripping profile for both ultrafast short circuit protection and overload protection. The …
Progressive switching of hybrid DC circuit breakers for faster fault isolation
L Mackey, C Peng, I Husain - 2018 IEEE Energy Conversion …, 2018 - ieeexplore.ieee.org
Achieving fast and efficient circuit protection is critical to direct current (DC) system safety
with many scholars focusing on hybrid direct current circuit breakers (DCCBs) to achieve this …
with many scholars focusing on hybrid direct current circuit breakers (DCCBs) to achieve this …
Design considerations of series type hybrid circuit breaker (S‐HCB)
The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously
reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid …
reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid …