An experimental study on a novel radiant-convective heating system based on air source heat pump
Air source heat pump (ASHP) has been widely applied to many parts of the world due to its
simple structure and low initial cost. To save energy consumed for spacing heating and …
simple structure and low initial cost. To save energy consumed for spacing heating and …
Experimental investigation and feasibility analysis on a capillary radiant heating system based on solar and air source heat pump dual heat source
Due to sustainable development, solar energy has drawn much attention and been widely
applied in buildings. However, the application of solar energy is limited because of its …
applied in buildings. However, the application of solar energy is limited because of its …
Comparative Economic and Experimental Assessment of Air Source Heat Pump and Gas-fired boiler: A Case Study from Turkey
O Kul, MN Uğural - Sustainability, 2022 - mdpi.com
Since sustainability has become a major concern in the construction industry, making
economically efficient investment decisions in energy conservation are needed to minimize …
economically efficient investment decisions in energy conservation are needed to minimize …
Experimental investigation on the heat transfer coefficients of radiant heating systems: Wall, ceiling and wall-ceiling integration
In recent years, radiant heating systems have been catching more observation under favor
of the advantages in energy saving and thermal comfort. Radiant ceiling systems are …
of the advantages in energy saving and thermal comfort. Radiant ceiling systems are …
An experimental study on frosting and defrosting performances of a novel air source heat pump unit with a radiant-convective heating terminal
When the outdoor air temperature is low and relative humidity is high, frost will occur and
accumulate on the outdoor coil of an ASHP unit, which may decrease the heating …
accumulate on the outdoor coil of an ASHP unit, which may decrease the heating …
[HTML][HTML] Investigation of the Temperature Distribution and Energy Consumption of an Integrated Carbon Fiber Paper-Embedded Electric-Heated Floor
C Huang, N Li, S He, X Weng, Y Shu, G Yang, Y Bao - Buildings, 2024 - mdpi.com
This study examined spatial and temporal thermal performance and energy consumption.
The temperature distribution in the running period was monitored in test rooms with …
The temperature distribution in the running period was monitored in test rooms with …
A comparison of heating and cooling systems having radiant and ventilation systems regarding thermal comfort
Thermal comfort is crucial for indoor environmental quality, impacting occupant well-being
and intellectual productivity. Despite the widespread use of HVAC technologies in …
and intellectual productivity. Despite the widespread use of HVAC technologies in …
Numerical evaluation of the indoor environment in a room with capillary radiation air conditioning system
L Zhang, D Yang, Y Zhang, Q Wen, J Liu - Procedia Engineering, 2016 - Elsevier
Numerical simulation has been conducted in a conference room with capillary radiation air
conditioning system in Jinan. The influence of the different supply air speed on the indoor …
conditioning system in Jinan. The influence of the different supply air speed on the indoor …
Experimental examination of heat transfer performance of the heated radiant wall system
A Koca - Journal of Thermal Engineering, 2018 - dergipark.org.tr
In recent years, radiant heating systems have been catching more observation under favor
of the many advantages such as; energy saving and thermal comfort. However, owing the …
of the many advantages such as; energy saving and thermal comfort. However, owing the …
[PDF][PDF] A new method that can be used to overcome the condensation risks in radiant cooling systems and thermal comfort examinations
A Koca - Journal of the Faculty of Engineering and Architecture …, 2018 - academia.edu
Results: In all studied cases, thermal comfort conditions were provided. The elapsed time to
reach the thermal comfort conditions was associated with the initial PMV value and panel …
reach the thermal comfort conditions was associated with the initial PMV value and panel …